Related Experiment Video
Updated: May 12, 2026

Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
Interreader scoring variability in an observer study using dual-modality imaging for breast cancer detection in women
Karen Drukker1, Karla J Horsch, Lorenzo L Pesce
1Department of Radiology, MC2026, University of Chicago, 5841 S Maryland Ave, Chicago, IL 60637, USA. kdrukker@uchicago.edu
Rationale And Objectives:
To evaluate variability in the clinical assessment of breast images, we evaluated scoring behavior of radiologists in a retrospective reader study combining x-ray mammography (XRM) and three-dimensional automated breast ultrasound (ABUS) for breast cancer detection in women with dense breasts.
Methods:
The study involved 17 breast radiologists in a sequential study design with readers first interpreting XRM-alone followed by an interpretation of combined XRM + ABUS. Each interpretation included a forced Breast Imaging Reporting and Data System scale and a likelihood that the woman had breast cancer. The analysis included 164 asymptomatic patients, including 31 breast cancer patients, with dense breasts and a negative screening XRM. Of interest were interreader scoring variability for XRM-alone, XRM + ABUS, and the sequential effect. In addition, a simulated double reading by pairs of readers of XRM + ABUS was investigated. Performance analysis included receiver operating characteristic analysis, percentile analysis, and κ statistics. Bootstrapping was used to determine statistical significance.
Results:
The median change in area under the receiver operating characteristic curve after ABUS interpretation was 0.12 (range 0.04-0.19). Reader agreement was fair with the median interreader κ being 0.26 (0.05-0.48) for XRM-alone and 0.34 (0.11-0.55) for XRM + ABUS (95% confidence interval for the difference in κ, 0.06-0.11). Simulated double reading of XRM + ABUS demonstrated tradeoffs in sensitivity and specificity, but conservative simulated double reading resulted in a significant improvement in both sensitivity (16.7%) and specificity (7.6%) with respect to XRM-alone.
Conclusion:
A modest, but statistically significant, increase in interreader agreement was observed after interpretation of ABUS.
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies II: Ultrasonography
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies IV: Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT

