Related Experiment Video
Updated: May 12, 2026

A Microfluidic Flow Chamber Model for Platelet Transfusion and Hemostasis Measures Platelet Deposition and Fibrin Formation in Real-time
Published on: February 14, 2017
Coagulation activity and white thrombus formation in the microminipig
Naoki Miura1, Hiroaki Kawaguchi, Tomoka Nagasato
1Kagoshima University Graduate School of Medical and Dental Sciences, 8-35-1, Sakuragaoka, Kagoshima, Japan.
Abstract:
Swine are becoming increasingly attractive as animal models for clinical research and the recently developed Microminipig (MMPig) has emerged as a possible experimental animal model. In this study, we demonstrated age-dependent changes in hematological parameters and coagulation activity in healthy MMPigs (58 male and 67 females, aged 0-34 months), and investigated white thrombus formation (WTF) using an in vitro microchip flow-chamber system (four males and four females, aged 22-23 months). There was no clear sex or age-dependent differences in any hematological parameters. While activated partial thromboplastin time (APTT) was shorter than prothrombin time (PT), with APTT:PT of 0.88:1, microchip flow-chamber system analysis showed that WTF time was shorter than that in humans, suggesting a possible thrombotic tendency in the MMPig. These results could be useful to life science researchers in the use of the MMPig as an experimental model animal for thrombus formation.