A Rat Carotid Artery Pressure-Controlled Segmental Balloon Injury with Periadventitial Therapeutic Application
Published on: July 9, 2020
Carotid artery thrombosis treated with catheter intervention using proximal occlusion and flow reversal
1Appleton Heart Institute, Cardiology Department, Appleton, Wisconsin, USA. kalaswad@gmail.com
Insights
This study demonstrates a novel catheter intervention technique for treating carotid artery thrombosis using a Gore Flow Reversal device. This approach safely removed the blockage, previously considered too high-risk for intervention.
Area of Science:
- Vascular Surgery
- Interventional Cardiology
- Neurology
Background:
- Carotid artery thrombosis poses a high risk of distal embolization, making catheter intervention traditionally contraindicated.
- Advances in embolic protection devices are expanding treatment options for complex vascular conditions.
Abstract:
We present a case of symptomatic carotid artery thrombosis treated with catheter intervention under proximal occlusion and flow reversal embolic protection. Although catheter intervention is contraindicated in carotid artery thrombosis due to the risk of distal embolization, the introduction of proximal occlusion embolic protection devices allow interventionalists to use catheter intervention where it was previously deemed too high a risk. A Gore Flow Reversal device was used in a 57-year-old male with obesity, uncontrolled type I diabetes mellitus, hypertension, hyperlipidemia, and prior stroke who had previously undergone left internal carotid artery revascularization with carotid artery endarterectomy and patch angioplasty. Since balloon disruption and manual aspiration through the balloon sheath of the flow reversal device was unable to remove the thrombosis, an AngioJet 4 Fr RX catheter was used to mechanically remove material via mechanical thrombectomy. As there was still residual stenosis, a stent was placed in the area to decrease the remaining blockage. Follow-up carotid artery duplex scanning showed that the procedure eliminated the carotid occlusion. The embolic protection device and the procedural technical aspects are described herein, as are reports of both clinical and anatomical follow-up. We show that by using a Gore Flow Reversal protection device, we were able to use catheter therapy to treat a carotid thrombosis, which was previously contraindicated for this condition.