Related Experiment Video
Updated: May 11, 2026

Detection of Architectural Distortion in Prior Mammograms via Analysis of Oriented Patterns
Published on: August 30, 2013
Digital compared with screen-film mammography: performance measures in concurrent cohorts within an organized breast
Anna M Chiarelli1, Sarah A Edwards, Maegan V Prummel
1Department of Prevention and Cancer Control, Cancer Care Ontario, 620 University Ave, Toronto, ON, Canada. anna.chiarelli@cancercare.on.ca
Purpose:
To evaluate the performance of digital direct radiography (DR) and computed radiography (CR) compared with that of screen-film mammography (SFM) in large concurrent cohorts.
Materials And Methods:
This study was approved by the University of Toronto Research Ethics Board and did not require informed consent. Concurrent cohorts of women aged 50-74 years screened with DR (n = 220 520), CR (n = 64 210), or SFM (n = 403 688) between 2008 and 2009 were identified and followed for 12 months. Performance was compared between cohorts, with SFM as the referent cohort. Associations were examined by using mixed-effect logistic regression.
Results:
The cancer detection rate was similar for DR (4.9 per 1000; 95% confidence interval [CI]: 4.7, 5.2) and SFM (4.8 per 1000; 95% CI: 4.7, 5.0); however, the rate was significantly lower for CR (3.4 per 1000; 95% CI: 3.0, 3.9) (odds ratio, 0.79; 95% CI: 0.68, 0.93). Recall rates were higher for DR (7.7%; 95% CI: 7.6%, 7.8%) and lower for CR (6.6%; 95% CI: 6.5%, 6.7%) than for SFM (7.4%; 95% CI: 7.3%, 7.5%). Positive predictive value was lower for CR (5.2%; 95% CI: 4.7%, 5.8%) than for SFM (6.6%; 95% CI: 6.4%, 6.8%); however, the adjusted odds were not significant.
Conclusion:
Although DR is equivalent to SFM for breast screening among women aged 50-74 years, the cancer detection rate was lower for CR. Screening programs should monitor the performance of CR separately and may consider informing women of the potentially lower cancer detection rates.