Workflow Based on the Combination of Isotopic Tracer Experiments to Investigate Microbial Metabolism of Multiple Nutrient Sources
Published on: January 22, 2018
Chemometric optimization of derivatization reactions prior to gas chromatography-mass spectrometry analysis
Jolanta Kumirska1, Alina Plenis, Paulina Łukaszewicz
1Institute for Environmental and Human Health Protection, Faculty of Chemistry, University of Gdańsk, Sobieskiego 18/19, 80-952 Gdańsk, Poland. kumirska@chem.univ.gda.pl
Abstract:
Derivatization is a methodological technique that can be used to make an organic compound more suitable for qualitative and/or quantitative analysis (e.g. pharmaceuticals). However, many analysts try to avoid this analytical procedure as it is time-consuming and labour-intensive. On the other hand, an inter-laboratory study demonstrated that with regard to sensitivity and measurement uncertainty, gas chromatography coupled to mass-spectrometry was superior to liquid chromatography coupled to mass spectrometry for the trace analysis of organic compounds in matrices of greater complexity. In our previous paper (Kumirska et al., J. Chemometr. 25 (2011) 636-643) we suggested using principal component analysis (PCA) to optimize the derivatization of six compounds (5 oestrogenic steroids and diethylstilbestrol) prior to GC-MS analysis. In the present work we applied a highly sophisticated model - 24 pharmaceuticals derived from six classes of drugs. The efficiency of different derivatization reactions was evaluated by PCA and compared with that obtained from cluster analysis (CA), the latter method being applied in this context for the first time. Derivatization using N,O-bis(trimethylsilyl)trifluoroacetamide (BSTFA) and 1% trimethylchlorosilane (TMCS) in pyridine and ethyl acetate (2:1:1, v/v/v) for 30min at 60°C was found to be optimal. The SPE-GC-MS method was also validated and successfully applied to the analysis of selected pharmaceuticals in wastewater and surface waters in Poland.
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...