Related Experiment Video
Updated: May 11, 2026

Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
Ionizing irradiation affects the microtensile resin dentin bond strength under simulated clinical conditions
1Department of Conservative Dentistry and Endodontics, SGT Dental College, Gurgaon, Haryana, India.
Objectives:
This study evaluated the effect of ionizing radiations on resin-dentin interface in terms of marginal adaptation and micro-tensile bond strength under thermocycling and mechanical loading.
Materials And Methods:
Forty extracted human mandibular third molars were divided into four groups. GR I: No Irradiation and Class II MO cavities were prepared that were restored with composite restorations; GR II: Teeth were irradiated and restored; GR III: Teeth were restored and irradiated; GR IV: Teeth were restored during irradiation dosage fractions. All samples were thermal and mechanical loaded with 5000 cycles, 5 ± 2-55 ± 2°C, dwell time 30 s and 150,000 cycles at 60N. Resin-dentin slabs were trimmed into dumbbell-shaped slabs and microtensile bond strength was measured. The bond strength data was analyzed by one-way analysis of variance test.
Results And Conclusions:
Irradiation before tooth preparation deteriorated the microtensile bond strength.