An Approach to Point-Of-Care Ultrasound Evaluation of the Abdominal Aorta
Published on: September 8, 2023
Subject body mass index affects Doppler waveform in celiac artery by duplex ultrasound
Akram M Asbeutah1, Yousif Y Bakir, Nayanatara Swamy
1Department of Radiologic Sciences, Faculty of Allied Health Sciences, Kuwait University, Kuwait.
Objective:
The aim of this study is to evaluate the effect of body mass index (BMI) on peak systolic velocity (PSV) recording in the celiac artery (CA).
Subjects & Methods:
Forty male participants were entered prospectively into the study. The subjects were divided into two groups according to their body mass index. Group A included subjects with BMI ≤25 Kg/m(2) and those in group B with BMI >25 Kg/m(2). The diameter and PSV at the origin of CA of subjects in both groups were recorded while the subject positioned in supine and during expiration phase and fasted for 4 hours using duplex ultrasound. Both groups were matched for age and sex. Independent Student's t-test was used to test if there is any statistical significance between diameter and PSV in both groups.
Results:
Group A's, average age (year, ±SD) was 29.35±1.35 and average BMI (Kg/m(2), ±SD) was 23.1±1.60. Group B's, average age was 30±2.1 and their average BMI was 31±5.1. The average diameter (cm, ±SD) of CA in group A was 0.66±0.076 and in group B was 0.80±0.066. However, the average PSV (cm/s, ±SD) was 117±28.1 in group A and 102±12.4 in group B. Independent student t-test showed statistical significance between both groups for the diameter (p=0.005) and just reached statistical significance for PSV (p=0.049).
Conclusion:
Subjects with higher BMI showed reduced PSV due to a larger CA diameter and probably due to more fatty tissue accumulation around the CA origin.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation