Related Experiment Video
Updated: May 10, 2026

Transcutaneous Microcirculatory Imaging in Preterm Neonates
Published on: December 31, 2015
Global perfusion assessment and tissue oxygen saturation in preterm infants: where are we?
Rosa Maria Cerbo1, Roberta Maragliano, Margherita Pozzi
1Neonatal Intensive Care Unit, Fondazione IRCCS-Policlinico San Matteo, Pavia, Italy. rm.cerbo@smatteo.pv.it
Abstract:
Near infrared spectroscopy (NIRS) monitoring is a new challenge for clinicians who deal with early detection of dangerous hypoperfusion in the brain, as well as in splanchnic and renal districts in critically ill preterm infants. Previous studies performed on infants and children with congenital heart disease, demonstrated the efficacy of this non-invasive method in managing hypoperfusive states pre, post and during cardiac surgery. Its use has improved post surgery outcome. NIRS monitoring has been used also to assess therapeutic intervention utility. Early identification of silent hypoperfusion has made NIRS use in preterm infants very interesting for neonatologists, especially where other techniques have failed. In this work, literature on this topic has been carefully examined, particularly the "two site NIRS" use in preterm infants, to evaluate how regional splanchnic oxygen saturation changes, both in physiological events, such as enteral feeding and in hemodynamic disorders, that occur in patients with significant patent ductus and in hypoperfusive states that lead to necrotizing enterocolitis.
More Related Videos
07:27How to Administer Near-Infrared Spectroscopy in Critically ill Neonates, Infants, and Children
Published on: August 19, 2020
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.