1Department of Ophthalmology, University of Ulsan, College of Medicine, Asan Medical Center, 388-1 Pungnap-2-dong, Songpa-gu, Seoul, Korea, 138-736.
Purpose:
To evaluate and compare the glaucoma detection capabilities afforded by retinal nerve fiber layer (RNFL) thickness and deviation maps obtained using Cirrus spectral domain optical coherence tomography (Cirrus OCT), and GDx employing variable corneal compensation (GDx-VCC) in glaucoma patients with early, localized visual field (VF) loss.
Methods:
This prospective controlled, comparative study was performed on 42 eyes with localized VF defects, and 42 age/refractive error-matched healthy eyes. All participants were imaged by both imaging devices at the same visit. The area of the RNFL defect in each deviation map, corresponding to a VF defect, was analyzed by direct counting of color-coded superpixels in each device. Receiver operating characteristic (ROC) curves were constructed and compared between Cirrus OCT and GDx-VCC.
Results:
The areas under the ROCs (AUCs) of RNFL quadrant thicknesses in hemifields with visual field (VF) defects did not differ significantly (Cirrus OCT; 0.961, GDx-VCC; 0.919, P = 0.07). However, Cirrus OCT afforded a better diagnostic ability, by deviation map analysis, than did GDx-VCC (0.972 vs 0.887, P = 0.02).
Conclusions:
The RNFL thicknesses assessed by either Cirrus OCT or GDx-VCC were comparable in terms of early glaucoma diagnostic capability. However, when areas containing RNFL defects were analyzed via deviation mapping, Cirrus OCT was better than GDx-VCC.
More Related Videos
07:45Assessing Binocular Central Visual Field and Binocular Eye Movements in a Dichoptic Viewing Condition
Published on: July 21, 2020
10:24Detecting Abnormalities in Choroidal Vasculature in a Mouse Model of Age-related Macular Degeneration by Time-course Indocyanine Green Angiography
Published on: February 19, 2014
Related Concept Videos
Glaucoma: Overview
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Angle Closure Glaucoma: Treatment