Spin exchange optical pumping based polarized 3He filling station for the Hybrid Spectrometer at the Spallation

C Y Jiang1, X Tong, D R Brown

  • 1Instrument and Source Design Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831, USA.

Related Concept Videos

Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation01:26

Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation

Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy  (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Nuclear Overhauser Enhancement (NOE)01:06

Nuclear Overhauser Enhancement (NOE)

Irradiation of a spin-active nucleus causes an increase or decrease in the signal intensity of neighboring nuclei that are not necessarily chemically bonded or involved in J-coupling. This phenomenon, called the nuclear Overhauser enhancement (NOE), results from through-space interactions between the nuclear spins. The NOE effect decreases with increasing internuclear distance and is generally not observed beyond 4 angstroms. In NOE, dipole-dipole interactions between neighboring spin-active...
Atomic Emission Spectroscopy: Instrumentation01:22

Atomic Emission Spectroscopy: Instrumentation

The instrumentation of atomic emission spectrometry (AES) involves various components, including atomization devices that convert samples into gas-phase atoms and ions. There are two main types of atomization devices: continuous and discrete atomizers.  Continuous atomizers, like plasmas and flames, introduce samples in a constant stream, while discrete atomizers inject individual samples using syringes or autosamplers. The most common discrete atomizer is the electrothermal atomizer.
Insensitive Nuclei Enhanced by Polarization Transfer (INEPT)01:15

Insensitive Nuclei Enhanced by Polarization Transfer (INEPT)

Insensitive Nuclei Enhanced by Polarization Transfer (INEPT) is an advanced Nuclear Magnetic Resonance (NMR) technique specifically designed to detect and enhance the signals of low-abundance nuclei, such as carbon-13 and nitrogen-15, in small molecules. The fundamental principle behind INEPT is the transfer of polarization from a more abundant and highly polarizable nucleus, typically hydrogen-1, to the low-abundance nucleus of interest. This process effectively boosts the NMR signal of the...
Atomic Emission Spectroscopy: Lab01:29

Atomic Emission Spectroscopy: Lab

AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...
Interpreting ¹H NMR Signal Splitting: The (n + 1) Rule01:10

Interpreting ¹H NMR Signal Splitting: The (n + 1) Rule

In the AX proton spin system, proton A can sense the two spin states of a coupled proton X, resulting in a doublet NMR signal with two peaks of equal (1:1) intensity. When proton A is coupled to two equivalent protons (AX2 spin system), the spin states of each X can be aligned with or against the external field, creating three possible scenarios. This results in a 1:2:1  triplet signal, where the central peak corresponds to the chemical shift of A and is twice as large or intense as the others.