Related Experiment Video
Updated: May 9, 2026

Assessment of Bone Fracture Healing Using Micro-Computed Tomography
Published on: December 9, 2022
Microstructure and homogeneity of distribution of mineralised struts determine callus strength
1Julius Wolff Institute for Biomechanics and Musculoskeletal Regeneration, Charité-Universitätsmedizin Berlin, Campus-Virchow Klinikum, Augustenburger Platz 1, Institutsgebäude Süd, 13353 Berlin, Germany. manavben@gmail.com
Abstract:
Non-invasive assessment of fracture healing, both in clinical and animal studies, has gained favour as surrogate measure to estimate regain of mechanical function. Micro-computed tomography (µCT) parameters such as fracture callus volume and mineralisation have been used to estimate callus mechanical competence. However, no in-depth information has been reported on microstructural parameters in estimating callus mechanical competence. The goal of this study is to use differently conditioned mice exhibiting good and impaired fracture healing outcomes and investigate the relationship between µCT imaging parameters (volume, mineralisation, and microstructure) that best estimate the callus strength and stiffness as it develops over time. A total of 99 mice with femoral fracture and intramedullary stabilisation were divided into four groups according to conditioning: wild type, NF1 knock-out, RAG1 knock-out and macrophage depleted. Animals were sacrificed at 14, 21, 28 or 35 days and µCT parameters and torsional stiffness and strength were assessed post-sacrifice. Using linear regression for all groups and time points together, torsional stiffness could be estimated with strut thickness, strut number and strut homogeneity (R² = 0.546, p < 0.0001); torsional strength could be estimated using bone mineral density, strut thickness and strut homogeneity (R² = 0.568, p < 0.0001). Differently conditioned mice that result in different fracture healing outcomes have been shown to result in varying structural, material and volumetric µCT parameters which can be used to estimate regain of bone strength. This study is the first to demonstrate that microstructure and strut homogeneity influence callus stiffness and strength.
Related Concept Videos
Tensile Strength Considerations of Concrete
The dimensions and shape of a concrete specimen also...
Hooke's Law
Bonding and Strength of Aggregate
Compact Bone
Compact bone, also called cortical bone, is the denser, stronger of the two types of bone tissue. It is found under the periosteum and in the diaphyses of long bones, where it provides support and protection. The microscopic structural unit of compact bone is called an osteon, or haversian system. Each osteon is composed of concentric rings of calcified...
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in ASTM C...
Stress-Strain Diagram - Brittle Materials

