WITHDRAWN: Bearing multi-faults diagnosis based on stator current bi-spectrum features and support vector machines

L Saidi1, F Fnaiech

  • 1University of Tunis, Higher School of Sciences and Techniques of Tunis, Laboratory of Signal Image and Energy Mastery (SIME), 5 avenue Taha Hussein. P.O. Box 96, 1008 Tunis, Tunisia; University of Picardie "Jules Verne", Department of Electrical Engineering, 33 rue Saint Leu, 80039 Amiens cedex 1, France.

ISA Transactions
|July 11, 2013
PubMed

Related Concept Videos

Three-Phase Short Circuit—Unloaded Synchronous Machine01:21

Three-Phase Short Circuit—Unloaded Synchronous Machine

Conducting a three-phase short circuit test on an unloaded synchronous machine helps understand its impact on the system. The AC fault current's oscillogram, with the DC offset removed, reveals that the waveform amplitude decreases from an initially high value to a steady-state level for one phase of the machine.
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
Multimachine Stability01:25

Multimachine Stability

Multimachine stability analysis is crucial for understanding the dynamics and stability of power systems with multiple synchronous machines. The objective is to solve the swing equations for a network of M machines connected to an N-bus power system.
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
Fault Types01:18

Fault Types

When analyzing a single line-to-ground fault from phase A to ground at a three-phase bus, it is important to consider the fault impedance. This impedance is zero for a bolted fault, equal to the arc impedance for an arcing fault, and represents the total fault impedance for a transmission-line insulator flashover. To derive sequence and phase currents, fault conditions are translated from the phase domain to the sequence domain.
For line-to-line faults occurring between phases B and C, the...
Power System Three-Phase Short Circuits01:21

Power System Three-Phase Short Circuits

Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
Classification of Signals01:30

Classification of Signals

In signal processing, signals are classified based on various characteristics: continuous-time versus discrete-time, periodic versus aperiodic, analog versus digital, and causal versus noncausal. Each category highlights distinct properties crucial for understanding and manipulating signals.
A continuous-time signal holds a value at every instant in time, representing information seamlessly. In contrast, a discrete-time signal holds values only at specific moments, often denoted as x(n), where...
Magnetic Field Of A Current Loop01:16

Magnetic Field Of A Current Loop

Consider a circular loop with a radius a, that carries a current I. The magnetic field due to the current at an arbitrary point P along the axis of the loop can be calculated using the Biot-Savart law.