Related Experiment Video
Updated: May 9, 2026

Through-the-Wall Blood Sampling Method to Minimize Sleep Disruption in Clinical Settings
Published on: June 13, 2025
Reproducibility of blood pressure dipping: relation to day-to-day variability in sleep quality
Alan L Hinderliter1, Faye S Routledge2, James A Blumenthal3
1University of North Carolina at Chapel Hill, Chapel Hill, NC.
Abstract:
Previous studies of the reproducibility of blood pressure (BP) dipping have yielded inconsistent results. Few have examined factors that may influence day-to-day differences in dipping. Ambulatory BP monitoring was performed on three occasions, approximately 1 week apart, in 115 untreated adult subjects with elevated clinic BPs. The mean ± standard deviation BP dip was 18 ± 7/15 ± 5 mm Hg (sleep/awake BP ratio = 0.87 ± 0.05/0.82 ± 0.06), with a median (interquartile range) day-to-day variation of 5.2 (3.1-8.1)/4.3 (2.8-5.6) mm Hg. There was no decrease in variability with successive measurements. The reproducibility coefficient (5.6 [95% confidence interval, 5.1-6.1] mm Hg) was greater and the intraclass correlation coefficient (0.53 [95% confidence interval, 0.42-0.63]) was smaller for the systolic dip than for 24-hour or awake systolic BPs, suggesting greater day-to-day variability in dipping. Variability in systolic dipping was greater in subjects with higher awake BP, but was not related to age, gender, race, or body mass index. Within individuals, day-to-day variations in dipping were related to variations in the fragmentation index (P < .001), a measure of sleep quality. Although mean 24-hour and awake BPs were relatively stable over repeated monitoring days, our study confirms substantial variability in BP dipping. Day-to-day differences in dipping are related to sleep quality.
Related Concept Videos
Measurement of Blood Pressure
Errors occurring during blood pressure monitoring
Several factors...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Factors affecting Blood pressure
Physiological Factors:
Chronopharmacokinetics: Circadian Rhythms and Influence on Drug Response
The time of drug administration is an important factor to consider, as it can influence the toxic dose of a drug. For example, a study conducted by Prins et al. in 1997 examined the effects of the timing of...

