Related Experiment Video
Updated: May 9, 2026

Y-90 Radioembolization and PD-1 Inhibitor as Neoadjuvant Treatment in Hepatocellular Carcinoma
Published on: May 24, 2024
Post-radioembolization yttrium-90 PET/CT - part 1: diagnostic reporting
Yung-Hsiang Kao1, Jeffrey D Steinberg, Young-Soon Tay
1Department of Nuclear Medicine and PET, Singapore General Hospital, Outram Road, Singapore 169608, Singapore. yung.h.kao@gmail.com.
Yttrium-90 (90Y) PET/CT offers superior assessment of tumor vascular thrombosis and non-target activity compared to SPECT/CT. Proper technique and continuity of care are crucial for maximizing the clinical utility of 90Y PET/CT in radioembolization.
Area of Science:
- Nuclear Medicine
- Radiology
- Oncology
Background:
- Yttrium-90 (90Y) positron emission tomography with integrated computed tomography (PET/CT) offers advanced imaging capabilities over traditional 90Y bremsstrahlung single-photon emission computed tomography with integrated computed tomography (SPECT/CT).
- The study implemented 90Y PET/CT as an adjunct to 90Y SPECT/CT for diagnostic reporting following radioembolization, building on positive initial experiences.
Purpose of the Study:
- To compare the diagnostic performance of 90Y PET/CT versus 90Y SPECT/CT in the post-radioembolization setting.
- To evaluate the ability of 90Y PET/CT to assess technical success, detect non-target activity, and confirm 90Y activity within targeted tumor vascular thrombosis.
Main Methods:
- A retrospective review of 44 paired 90Y PET/CT and 90Y SPECT/CT scans was conducted over one year.
- Image resolution, technical success confirmation, non-target activity detection, and tumor vascular thrombosis assessment were compared.
- 90Y PET/CT findings were corroborated using various methods, including SPECT/CT, follow-up imaging, and clinical record review.
Main Results:
- 90Y PET/CT consistently outperformed 90Y SPECT/CT in qualitative analysis, including assessment of non-target activity and tumor vascular thrombosis.
- A novel technique for detecting non-target activity based on activity patterns relative to anatomy was proposed.
- While generally superior, challenges remain in detecting non-target activity in viscera adjacent to the liver due to potential mis-registration.
Conclusions:
- Post-radioembolization 90Y PET/CT is clinically superior to 90Y SPECT/CT for evaluating both target and non-target Yttrium-90 activity.
- Adherence to proper diagnostic reporting techniques and maintaining continuity of care are essential for the effective clinical application of 90Y PET/CT.
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care
