Related Experiment Video
Updated: May 9, 2026

Development of a Novel Internal Fixation Model for Rat Radial Fractures: Fracture Healing Assessment and Dorsal Root Ganglion Isolation
Published on: March 13, 2026
Functional outcome in patients with unstable distal radius fractures, volar locking plate versus external fixation: a
Monique M J Walenkamp1, Abdelali Bentohami, M Suzan H Beerekamp
1Trauma Unit, Department of Surgery, Academic Medical Center Amsterdam, Po Box 22660, 1100 DD, Amsterdam, The Netherlands, m.m.walenkamp@amc.nl.
Abstract:
The aim of this study was to compare bridging external fixation with volar locked plating in patients with unstable distal radial fractures regarding functional outcome. A systematic search was performed in the Cochrane Central Register of Controlled Trials, Medline and EMBASE. All randomized controlled trials that compared bridging external fixation directly with volar locked plating in patients with distal radial fractures were considered. Three reviewers extracted data independently from eligible studies using a data collection form. Studies in which the primary endpoint was measured on the disabilities of the arm shoulder and hand (DASH) score at 3, 6 and 12 months were included in the analysis. To this end, mean scores and standard deviations were extracted. The software package Revman 5 provided by the Cochrane Collaboration was used for data analysis. Three studies involving 174 patients were analyzed. Ninety patients were treated with an (augmented) bridging external fixator and 84 with a volar locking plate. Data were analyzed with the random effects model. The robustness of the results was explored using a sensitivity analysis. Patients treated with a volar locking plate showed significantly lower DASH scores at all times. A difference of 16 (p = 0.006), six (p = 0.008) and eight points (p = 0.06) was found at 3, 6 and 12 months follow-up, respectively. Patients treated with a volar locking plate showed significantly better functional outcome throughout the entire follow-up. However, this difference was only clinically relevant during the early postoperative period (3 months).
More Related Videos
15:11Surgical Fixation of Sternal Fractures: Preoperative Planning and a Safe Surgical Technique Using Locked Titanium Plates and Depth Limited Drilling
Published on: January 5, 2015
04:41Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025