Related Experiment Video
Updated: May 9, 2026

Standard Test Method ASTM D 7998-19 for the Cohesive Strength Development of Wood Adhesives
Published on: May 17, 2020
Improved long-term bonding performance of an experimental all-in-one adhesive
Shinichi Kakuda1, Jiale Fu, Yasuko Nakaoki
1Department of Restorative Dentistry, Division of Oral Health Science, Graduate School of Dental Medicine, Hokkaido University, Kita 13, Nishi 7, Kita-ku, Sapporo 060-8586, Japan. sk19766791ks@yahoo.co.jp
Abstract:
The aim of this study was to determine the performance of an experimental all-in-one adhesive. The adhesive, named MTB-200 (Kuraray Medical), contained components to enhance both bond strength and hydrophobicity. The performance of the adhesive was compared with that of CLEARFIL TRI-S BOND (Kuraray Medical) and BeautiBond (SHOFU) using micro-tensile bond strength test and ultramicroscopic observations. The study revealed that the new adhesive had the highest tensile strength value among the three adhesives over time, although transmission electron microscopic images showed the phenomenon of filler de-bonding in the adhesive resin layer. In spite of modification in the experimental adhesive, the adhesive was suspected to degrade bond performance. However, revision of the composition of adhesives would be one of the solutions to enhance durability of interface.
Related Concept Videos
Bonding and Strength of Aggregate
Adhesion
Capillary action is a result of water’s adhesive tendencies. When a narrow glass...
Mortar Properties
Accelerated Curing of Concrete