Image quality and radiation exposure in CT of the pancreas: 320-MDCT with and without adaptive iterative dose reduction versus 64-MDCT
Related Experiment Video
Updated: May 9, 2026

Dynamic Contrast Enhanced Magnetic Resonance Imaging of an Orthotopic Pancreatic Cancer Mouse Model
Published on: April 18, 2015
S Goshima1, M Kanematsu, H Nishibori
1Department of Radiology, Gifu University Hospital, Gifu, Japan.
Aim:
To compare the image quality and radiation exposure in computed tomography (CT) of the pancreas acquired using 320-multidetector (MD)CT versus 64-MDCT and to demonstrate the effects of adaptive iterative dose reduction (AIDR) on 320-MDCT.
Materials And Methods:
One hundred and fifty patients were randomized into three groups including 320-section volume imaging using AIDR (group A), 320-slice volume scan without AIDR (group B), and 64-section helical imaging without AIDR (group C). Transaxial arterial, pancreatic phase, and volume-rendered CT angiographic images were reconstructed. CT radiodensity of the abdominal aorta, pancreas, signal-to-noise ratios (SNR), dose-length products (DLPs; mGy cm), and image quality were measured.
Results:
No significant difference in CT radiodensity of the abdominal aorta or pancreas was noted between groups. Mean DLPs were 600.9 ± 145.8, 681.6 ± 97.5, and 1231.5 ± 271.4 in groups A, B, and C, respectively. The DLP was reduced by 51% in group A and 45% in group B compared to group C (p < 0.001). SNRs of the pancreas during the pancreatic phase were comparable between groups A and C, but were significantly lower in group B (p < 0.001). Image quality, including the depiction of some small arterial branches on the arterial and CT angiographic images and the main pancreatic duct on the pancreatic-phase images, were significantly lower in group B than in groups A and C (p = 0.008-0.038).
Conclusion:
Radiation dose can be markedly reduced for contrast-enhanced CT imaging of the pancreas without compromising image quality using a 320-MDCT with AIDR, compared with 64-section helical CT.
Related Concept Videos
Imaging Studies III: Computed Tomography
Radiological Investigation I: X-ray and CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...