Multimodal Volumetric Retinal Imaging by Oblique Scanning Laser Ophthalmoscopy (oSLO) and Optical Coherence Tomography (OCT)
Published on: August 4, 2018
Swept source optical coherence microscopy using a 1310 nm VCSEL light source.
Osman O Ahsen1, Yuankai K Tao, Benjamin M Potsaid
1Department of Electrical Engineering & Computer Science and Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA, USA.
High-speed swept source optical coherence microscopy (OCM) utilizes a MEMS-VCSEL laser for rapid imaging. This advanced microscopy technique achieves high resolution in biological tissues, enabling detailed ex vivo specimen analysis.
Area of Science:
- Biomedical Optics
- Microscopy Technology
- Medical Imaging
Background:
- Optical Coherence Microscopy (OCM) offers high-resolution cross-sectional imaging.
- Swept-source OCM requires fast, tunable laser sources for efficient data acquisition.
- Existing OCM systems may have limitations in speed, resolution, or flexibility.
Purpose of the Study:
- To demonstrate a high-speed swept-source OCM system.
- To utilize a MEMS-tunable vertical cavity surface-emitting laser (VCSEL) as the light source.
- To evaluate the system's performance in imaging biological tissues.
Main Methods:
- Employed a MEMS-tunable VCSEL with a 280 kHz sweep rate for bidirectional axial scanning at 560 kHz.
- Achieved an axial resolution of 8.1 µm in tissue using a 117 nm bandwidth centered at 1310 nm.
- Implemented numerical dispersion mismatch compensation and path length correction for enhanced image quality and flexibility.
- Acquired images with transverse resolutions from 0.86 µm to 3.42 µm and fields of view up to ~2 mm x 2 mm.
- Generated large field-of-view mosaics from serially acquired overlapping microscopic fields.
Main Results:
- Demonstrated high-speed OCM imaging with a 560 kHz bidirectional axial scan rate.
- Achieved high transverse and axial resolutions suitable for microscopic tissue analysis.
- Successfully imaged fresh human colon, thyroid, and kidney specimens ex vivo.
- Validated OCM image accuracy by comparison with corresponding histology sections.
Conclusions:
- The developed swept-source OCM system provides high-speed, high-resolution imaging capabilities.
- The system's flexibility in magnification and field of view facilitates integration with various microscopy setups.
- OCM is a viable technique for detailed ex vivo imaging and analysis of biological tissue specimens.
More Related Videos
14:09High-Throughput Total Internal Reflection Fluorescence and Direct Stochastic Optical Reconstruction Microscopy Using a Photonic Chip
Published on: November 16, 2019
12:54Simultaneous Brightfield, Fluorescence, and Optical Coherence Tomographic Imaging of Contracting Cardiac Trabeculae Ex Vivo
Published on: October 2, 2021
Related Concept Videos
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Confocal Fluorescence Microscopy
Total Internal Reflection Fluorescence Microscopy
Super-resolution Fluorescence Microscopy
Overview of Microscopy Techniques