Related Experiment Video
Updated: May 8, 2026

The Rigid Tube as an Alternative in Controlling the Problematic Airway
Published on: June 6, 2020
Double-lumen tube tracheal intubation using a rigid video-stylet: a randomized controlled comparison with the
1Department of Anesthesiology and Pain Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.
Background:
Despite an increasing need, there is limited experience of double-lumen endobronchial tube (DLT) placement using video laryngoscope. We evaluated DLT intubation using an OptiScope, a rigid video-stylet with a malleable tip derived from the Clarus Video System, in comparison with a Macintosh laryngoscope.
Methods:
After airway evaluation and anaesthetic induction, Cormack and Lehane (C and L) grade was initially assessed in all patients using a Macintosh laryngoscope before tracheal intubation. The trachea was then intubated using either a Macintosh laryngoscope (n=200) or an OptiScope® (n=200). Success rate, intubation time, number of attempts at intubation, vocal cord view during intubation, need for external manipulation, and the incidences of oral mucosal or dental injury were compared between the two devices.
Results:
Data were analysed for 397 patients. Intubation time with the OptiScope® was faster [median (inter-quartile range): 15 (12-19) s] than with the Macintosh [18(12-28) s] {mean difference [95% confidence interval (CI)}: 5.5 (3.8-13.2) s, P=0.010]. The success rate of the first intubation was higher with the OptiScope® than with the Macintosh [80.4% vs 89.9%, odds ratio (95% CI): 2.2 (1.22-3.87), P=0.036]. Initial view of the vocal cords was also better, although the final success rate was not different between devices. The need for external laryngeal manipulation, oral mucosal, or dental injury was lower with the OptiScope® compared with the Macintosh laryngoscope (all P<0.01).
Conclusions:
The OptiScope® provides faster tracheal intubation and a higher success rate for the first intubation with less trauma and a better vocal cord view than the Macintosh laryngoscope.
Related Concept Videos
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals.
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Tracheostomy Care II: Procedure
Step 1: Perform hand hygiene, and put on personal protective equipment: gown, gloves, mask and...

