Motion artifact suppression in the ECG signal by successive modifications in frequency and time
Abstract:
Ambulatory electrocardiogram signals can be contaminated with various types of noise. Among these, electrode motion 'em' artifacts are considered particularly undesired as they can be mistaken for ectopic beats. Unfortunately, 'em' noise has proved difficult to tackle using ordinary filtering techniques. In this paper, we explore a novel filtering alternative, and show that it could be considered as a potential candidate for dealing with electrode motion artifacts. The proposed system is composed of two simple parts: a frequency filter and a time window, interconnected in series. The two components are designed such that the overall system operates optimally in the mean square error sense. Experimentation on signals obtained from the MIT-BIH database demonstrates the superiority of the above approach over optimal Fourier filtering.
More Related Videos
11:25Simultaneous Scalp Electroencephalography EEG, Electromyography EMG, and Whole-body Segmental Inertial Recording for Multi-modal Neural Decoding
Published on: July 26, 2013
10:23Equipment Setup and Artifact Removal for Simultaneous Electroencephalogram and Functional Magnetic Resonance Imaging for Clinical Review in Epilepsy
Published on: June 23, 2023
Related Concept Videos
Instrumentation Amplifier
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias