Assessing Cerebral Autoregulation via Oscillatory Lower Body Negative Pressure and Projection Pursuit Regression
Published on: December 10, 2014
BaroLoop: using a multichannel cuff electrode and selective stimulation to reduce blood pressure
Abstract:
The therapy of refractory hypertension is an increasing problem for health care systems and a frontend in research in both pharmacology and neuroelectronic engineering. Overriding the baroreceptive information of afferent nerve fibers, originating from pressure sensors in the aortic arch, can trigger the baroreflex, a systemic control system that lowers the blood pressure (BP) almost instantaneously. Using a multichannel cuff electrode, wrapped around a rat vagal nerve, we were able to regulate the BP using selective, tripolar stimulation. The tripolar stimulation was sufficiently selective to not trigger any unwanted side effects like bradycardia or bradypnea. The BP was reduced best with charge balanced stimulation amplitudes of 1 mA and pulse duration of 0.3 ms. The stimulation frequency had only a mild influence on the effectiveness of the stimulation and did work best at 40 Hz. We found that the BP took up to five times the stimulation period to recover to the value prior to stimulation.
Related Concept Videos
Neural Regulation of Blood Pressure
Baroreceptor Reflex
Baroreceptors, located in the carotid sinuses and aortic arch, detect changes in blood pressure. When blood pressure rises, these stretch-sensitive receptors...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement