Summary

Magnetoencephalography (MEG) can measure brain signals noninvasively. A new AMUSE-based method effectively removes metallic artifacts, a common problem in MEG, improving signal quality for medical evaluations.

Related Concept Videos

Biasing of Metal-Semiconductor Junctions01:27

Biasing of Metal-Semiconductor Junctions

Biasing metal-semiconductor junctions involves applying a voltage across the junction. Specifically, the metal is connected to a voltage source, while the semiconductor is grounded. This technique is essential for controlling the direction and magnitude of current flow in electronic devices, including diodes, transistors, and photovoltaic cells.
In Schottky junctions, where the semiconductor is n-type, applying a positive voltage to the metal relative to the semiconductor reduces its Fermi...
921
Instrumentation Amplifier01:25

Instrumentation Amplifier

An electrocardiography (ECG) machine is an essential piece of medical equipment used to monitor the electrical activity of the heart. It operates by detecting small electrical changes on the skin that result from the depolarization of the heart muscle during each heartbeat. However, these signals are in the microvolt range and can be easily overwhelmed by noise or interference.
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
1.3K
Small-Signal Analysis of MOSFET Amplifiers01:23

Small-Signal Analysis of MOSFET Amplifiers

In small-signal analysis, a MOSFET transistor amplifier acts as a linear amplifier when operating in its saturation region. The gate-to-source voltage (VGS) of the MOSFET is the sum of the DC biasing voltage and the small time-varying input signal. This combination sets up the operating point and modulates the drain current (ID) that flows from the drain to the source. When a small AC signal is superimposed on the DC bias voltage at the gate, the instantaneous drain current comprises three...
1.4K
Atomic Emission Spectroscopy: Interference01:30

Atomic Emission Spectroscopy: Interference

In atomic emission spectroscopy (AES), high-temperature atomizers excite a broad range of elements and molecules that generate complex emissions from sources such as oxides, hydroxides, and flame combustion products in the flame or plasma. Several strategies can be employed to minimize spectral interferences caused by overlapping emission lines or bands. These include increasing instrument resolution, choosing alternative emission lines, optimally placing the detector in low-background regions,...
793
MOSFET Amplifiers01:17

MOSFET Amplifiers

The MOSFET, when operating in its active region, functions as a voltage-controlled current source. In this region, the gate-to-source voltage controls the drain current. This principle underlies the operation of the transconductance MOSFET amplifier. The output current is directed through a load resistor to convert this amplifier into a voltage amplifier. The output voltage is then obtained by subtracting the voltage drop across the load resistance from the supply voltage. This process results...
787
Mass Analyzers: Overview01:13

Mass Analyzers: Overview

The mass analyzer is a crucial component of the mass spectrometer. In the ionization chamber, the vaporized sample is bombarded with a high-energy electron beam to generate a radical cation and further fragment into neutral molecules, radicals, and cations. A series of negatively charged accelerator plates accelerate the cations into the mass analyzer. The mass analyzer separates ions according to their mass-to-charge (m/z) ratios and then directs them to the detector. The common types of mass...
2.1K