Shape-preserving preprocessing for human pulse signals based on adaptive parameter determination
IEEE Transactions on Biomedical Circuits and Systems
|October 26, 2013
Summary
A new signal preprocessing method enhances traditional Chinese medicine pulse diagnosis. This technique effectively removes noise while preserving vital pulse waveform information for accurate automated analysis.
Area of Science:
- Biomedical Engineering
- Traditional Chinese Medicine
- Signal Processing
Background:
- The human pulse signal is crucial for medical diagnosis in Traditional Chinese Medicine (TCM).
- Automating pulse signal analysis can improve diagnostic accuracy and efficiency.
- Existing methods struggle with baseline distortion and background noise in pulse waveforms.
Purpose of the Study:
- To develop a novel preprocessing method for human pulse signals.
- To improve feature extraction and classification accuracy for automated pulse diagnosis.
- To effectively remove baseline distortion and residual noise while preserving key waveform characteristics.
Main Methods:
- Utilized the dual-tree complex wavelet transform (DT-CWT) and cubic spline interpolation to remove baseline distortion.
- Implemented a two-stage filtering process: an adaptive mean filter and a second DT-CWT pass with novel thresholding.
- Employed a chain code and DT-CWT to automatically determine the adaptive mean filter's window duration.
Main Results:
- Successfully removed baseline distortion and residual background noise from the human pulse signal.
- Demonstrated excellent preservation of pulse peak information, crucial for accurate analysis.
- The preprocessing method significantly improved the quality of the waveform for feature extraction.
Conclusions:
- The proposed signal preprocessing technique effectively addresses noise and distortion in human pulse signals.
- This method enhances the potential for automated, accurate pulse-based medical diagnosis.
- Preservation of essential pulse waveform features is key to the method's success.
More Related Videos
Related Concept Videos
Rectangular and Triangular Pulse Function
2.3K
The unit rectangular pulse function is mathematically represented by a rectangular function centered at the origin with a height of one unit. This function is defined by two parameters: T, which specifies the center location of the pulse along the time axis, and τ, which determines the pulse duration.
For example, consider a rectangular pulse with a 5V amplitude, a 3-second duration, and centered at t=2 seconds. This pulse can be expressed using the rectangular function, written as,
For example, consider a rectangular pulse with a 5V amplitude, a 3-second duration, and centered at t=2 seconds. This pulse can be expressed using the rectangular function, written as,
2.3K
Special considerations while measuring pulse
1.0K
Assessing a patient's pulse is a fundamental skill in healthcare, but certain situations require special attention:
1.0K
Reconstruction of Signal using Interpolation
924
Signal processing techniques are essential for accurately converting continuous signals to digital formats and vice versa. When a continuous signal is sampled with a period T, the resulting sampled signal exhibits replicas of the original spectrum in the frequency domain, spaced at intervals equal to the sampling frequency. To handle this sampled signal, a zero-order hold method can be applied, which creates a piecewise constant signal by retaining each sample's value until the next...
924