Related Experiment Video
Updated: May 6, 2026

The Use of Gas Chromatography to Analyze Compositional Changes of Fatty Acids in Rat Liver Tissue during Pregnancy
Published on: March 13, 2014
Improved gas chromatography-flame ionization detector analytical method for the analysis of epoxy fatty acids
Edward Mubiru1, Kshitij Shrestha, Antonios Papastergiadis
1nutriFOODchem Unit, Department of Food Safety and Food Quality (Partner in Food2Know), Faculty of Bioscience Engineering, Ghent University, Ghent, Belgium.
Abstract:
In this study an improved method for analysis of epoxy fatty acids is reported. Data obtained from analysis of polar fatty acids has previously been presented, but due to the high number of compounds that co-elute in the polar fraction, the resultant chromatograms are complex which may lead to compromising the accuracy of the data. A three steps separation of fatty acid methyl esters (FAMEs) by solid-phase extraction (SPE) on a silica gel column to remove hydroxy fatty acid interferences was proposed. This approach is opposed to a two step separation procedure that has been often used to prevent analytical interferences caused by non-altered fatty acids. A gas chromatograph with a flame ionization detector (GC-FID) equipped with a polar CP-Sil 88™ column was used. Quantification was based on the use of methyl nonadecanoate (C19:0), as an internal standard. Individual mono epoxy fatty acids were well separated without co-eluting compounds. The optimized method was finally applied to screen epoxy fatty acids in 37 fresh oil samples. Results obtained for the total epoxy fatty acids were in the range 0.03-2mgg(-1) of oil with repeatability coefficient of variation (CV) ranging from 2.8 to 9.9% for duplicate analysis showing that the results obtained are repeatable.
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Flame Photometry: Lab
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Flame Photometry: Overview
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....

