Related Experiment Video
Updated: May 6, 2026

Dosimetry for Cell Irradiation using Orthovoltage 40-300 kV X-Ray Facilities
Published on: February 20, 2021
Frequency and collective dose of medical procedures in Kenya
Geoffrey K Korir1, Jeska S Wambani, Ian K Korir
1*Department of Physics and Applied Physics, University of Massachusetts Lowell, One University Avenue, Lowell, MA 01854; †Radiology Department, Kenyatta National Hospital, Hospital Road, P.O. Box 20723-00202 Nairobi, Kenya; ‡National Nuclear Regulator, Eco Glades 2 Office Park, Block G, Eco Park, Centurion, 0157 South Africa.
Abstract:
The first comprehensive national survey on frequency and radiation dose imparted to the population from radiological procedures was carried out in Kenya and reported here. This survey involved assessment of frequency, typical patient radiation exposure, and collective effective dose from general radiography, fluoroscopy, interventional procedures (IPs), mammography, and computed tomography. About 300 x-ray facilities across the country were invited to participate in the survey, and a 31% response was recorded. The individual and collective radiation burdens of more than 62 types of pediatric and adult radiological examinations were quantified using effective and collective dose. The average effective dose for each radiological examination was assessed from the x-ray efficiency performance tests and patient data from over 30 representative radiological facilities. The results found indicated that over 3 million x-ray procedures were performed in 2011, resulting in an annual collective effective dose of 2,157 person-Sv and an annual effective dose per capita of 0.05 mSv. The most frequent examinations were general radiography (94%), computed tomography (3.3%), and fluoroscopy (2.5%). Although the contribution of computed tomography was small in terms of frequency, this procedure accounted for 36% of the effective dose per capita. General radiography was the most frequent type of examination with a contribution of 55% of the effective dose per capita.
Related Concept Videos
Dosage Regimens: Partial Pharmacokinetic Parameters
Dose Size and Dosing Frequency: Determination Methods
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations
Healthcare Associated Infections II: Preventive Measures
The best practices for preventing healthcare-associated infections include hand hygiene, patient risk...
Drug Accumulation During Multiple Dosing: Intermittent IV Infusions
Biological Effects of Radiation

