Related Experiment Video
Updated: May 6, 2026

Selected Reaction Monitoring Mass Spectrometry for Absolute Protein Quantification
Published on: August 17, 2015
Evaluation of interspecimen trypsin digestion efficiency prior to multiple reaction monitoring-based absolute protein
Irene van den Broek1, Nico P M Smit, Fred P H T M Romijn
1Department of Clinical Chemistry and Laboratory Medicine, Leiden University Medical Center (LUMC) , Albinusdreef 2, 2333 ZA, Leiden, the Netherlands.
Abstract:
Implementation of quantitative clinical chemistry proteomics (qCCP) requires targeted proteomics approaches, usually involving bottom-up multiple reaction monitoring-mass spectrometry (MRM-MS) with stable-isotope labeled standard (SIS) peptides, to move toward more accurate measurements. Two aspects of qCCP that deserve special attention are (1) proper calibration and (2) the assurance of consistent digestion. Here, we describe the evaluation of tryptic digestion efficiency by monitoring various signature peptides, missed cleavages, and modifications during proteolysis of apolipoprotein A-I and B in normo- and hypertriglyceridemic specimens. Absolute quantification of apolipoprotein A-I and B was performed by LC-MRM-MS with SIS peptide internal standards at two time points (4 and 20 h), using three native protein calibrators. Comparison with an immunoturbidimetric assay revealed recoveries of 99.4 ± 6.5% for apolipoprotein A-I and 102.6 ± 7.2% for apolipoprotein B after 4 h of trypsin digestion. Protein recoveries after 20 h trypsin incubation equaled 95.9 ± 6.9% and 106.0 ± 10.0% for apolipoproteins A-I and B, respectively. In conclusion, the use of metrologically traceable, native protein calibrators looks promising for accurate quantification of apolipoprotein A-I and B. Selection of rapidly formed peptides, that is, with no or minor missed cleavages, and the use of short trypsin incubation times for these efficiently cleaved peptides are likely to further reduce the variability introduced by trypsin digestion and to improve the traceability of test results to reach the desirable analytical performance for clinical chemistry application.
More Related Videos
12:11Simultaneous Affinity Enrichment of Two Post-Translational Modifications for Quantification and Site Localization
Published on: February 27, 2020
10:37Deep Proteome Profiling by Isobaric Labeling, Extensive Liquid Chromatography, Mass Spectrometry, and Software-assisted Quantification
Published on: November 15, 2017