Related Experiment Video
Updated: May 5, 2026

Characterization and Application of Passive Samplers for Monitoring of Pesticides in Water
Published on: August 3, 2016
Field calibration of low density polyethylene passive samplers for gaseous POPs
Mohammed A Khairy1, Rainer Lohmann
1Graduate School of Oceanography, University of Rhode Island, 215 South Ferry Road, Narragansett, Rhode Island 02882, USA. mohammed_khairy77@yahoo.com.
Abstract:
A field calibration study of low density polyethylene (LDPE) for measuring atmospheric concentrations of persistent organic pollutants (POPs) was performed in East Providence (RI), USA. LDPE samplers were collected after 3, 7, 10, 14, 17 and 21 days of exposure along with samples from a co-deployed high volume sampler. Uptake kinetics of POPs by LDPEs were confirmed both by using an uptake study over time and the inclusion of performance reference compounds (PRCs). Results indicated that only POPs with log sampler-air partitioning coefficient (KPE-A) ≤ 7.6 were approaching equilibrium by the end of the deployment period, whereas all the other POPs were still in the linear uptake rate. Sampling rates (1.0-80 m(3) per day) were higher for some POPs when compared to literature values possibly due to the open sampler housing design used. Derived KPE-As for the detected POPs in field calibration study were correlated against the compounds' octanol-air partitioning coefficients (log KOA): [log KPE-A = 0.88 ± 0.02 × log KOA + 0.40 ± 0.21 (R(2) = 0.96; n = 59; SE = 0.23)], and their subcooled liquid vapour pressures (log PL/Pa): [log KPE-A = -0.82 ± 0.02 × log PL + 6.22 ± 0.05 (R(2) = 0.96; n = 59; SE = 0.22)] to predict values for all POPs. PL was generally found to be a better predictor of KPE-A for all POPs.
More Related Videos
10:29Calibrated Passive Sampling - Multi-plot Field Measurements of NH3 Emissions with a Combination of Dynamic Tube Method and Passive Samplers
Published on: March 21, 2016
08:18Design and Use of a Full Flow Sampling System FFS for the Quantification of Methane Emissions
Published on: June 12, 2016
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...