Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Brain Charts for the Rhesus Macaque Lifespan.

bioRxiv : the preprint server for biology·2024
Same author

Implant position for supporting maxillary over-denture: a clinical study.

Journal of biological regulators and homeostatic agents·2019
Same author

Bone strain measurements and implant micro-surface analysis of drill-less self-threading dental implants - preliminary in-vitro results.

Journal of biological regulators and homeostatic agents·2019
Same author

HIV infection among men who have sex with men in Israel: a 35-year epidemiological and clinical overview, 1981-2015.

BMC public health·2019
Same author

The relation between gain in cognition during rehabilitation on functional outcome among hip fracture adult patients with and without pre- hip fracture dementia.

Archives of gerontology and geriatrics·2018
Same author

Coverage of multiple recessions using the tunnel technique and a collagen matrix in the maxilla or mandible: a 6-month study.

Journal of biological regulators and homeostatic agents·2018

Related Experiment Video

Updated: Jan 4, 2026

Effects of Mechanical Methods Used in Peri-implantitis Treatment on Implant Surface Decontamination and Roughness
06:36

Effects of Mechanical Methods Used in Peri-implantitis Treatment on Implant Surface Decontamination and Roughness

Published on: March 14, 2025

716

[Impressions for implant supported prostheses].

N Harel1, S Livne, D Piek

  • 1Dept. of Oral rehabilitation, the Maurice and Gabriela Goldschleger School of Dental Medicine, Tel Aviv University, Tel Aviv, Israel.

Refu'At Ha-Peh Veha-Shinayim (1993)
|December 6, 2013
PubMed
Summary

Accurate implant restorations depend on precise master casts. This review examines impression materials and techniques, considering implant factors affecting cast accuracy for better dental outcomes.

More Related Videos

Oral Biofilm Formation on Different Materials for Dental Implants
11:19

Oral Biofilm Formation on Different Materials for Dental Implants

Published on: June 24, 2018

12.0K
Bioelectric Analyses of an Osseointegrated Intelligent Implant Design System for Amputees
14:31

Bioelectric Analyses of an Osseointegrated Intelligent Implant Design System for Amputees

Published on: July 14, 2009

14.4K

Related Experiment Videos

Last Updated: Jan 4, 2026

Effects of Mechanical Methods Used in Peri-implantitis Treatment on Implant Surface Decontamination and Roughness
06:36

Effects of Mechanical Methods Used in Peri-implantitis Treatment on Implant Surface Decontamination and Roughness

Published on: March 14, 2025

716
Oral Biofilm Formation on Different Materials for Dental Implants
11:19

Oral Biofilm Formation on Different Materials for Dental Implants

Published on: June 24, 2018

12.0K
Bioelectric Analyses of an Osseointegrated Intelligent Implant Design System for Amputees
14:31

Bioelectric Analyses of an Osseointegrated Intelligent Implant Design System for Amputees

Published on: July 14, 2009

14.4K

Area of Science:

  • Dental materials science
  • Prosthodontics
  • Biomaterials engineering

Context:

  • Accurate fit of implant-supported restorations is critical for long-term success.
  • Discrepancies between implants and prosthetic components can cause stress, potentially leading to implant failure.
  • Master cast accuracy is paramount, influenced by both clinical procedures and laboratory techniques.

Purpose:

  • To review and discuss various impression materials and methods used in implant dentistry.
  • To analyze the impact of implant location, number, and angulation on impression accuracy.
  • To provide insights into optimizing master cast accuracy for implant restorations.

Summary:

  • The precision fit between dental implants and prosthetic components is essential for successful restoration outcomes.
  • Small inaccuracies in the fit can induce stress on implants during restoration connection.
  • Master cast accuracy is significantly influenced by clinical and laboratory factors, including impression techniques and materials.
  • Factors such as implant position, quantity, and angulation critically affect the fidelity of the impression and subsequent cast.

Impact:

  • Improved understanding of factors influencing master cast accuracy in implant dentistry.
  • Guidance for clinicians and dental technicians in selecting appropriate impression materials and techniques.
  • Potential for reducing stress on implants and enhancing the longevity of implant-supported restorations.
  • Foundation for further research into novel impression methods for complex implant cases.