The accuracy of eyelid movement parameters for drowsiness detection
Vanessa E Wilkinson1, Melinda L Jackson, Justine Westlake
1Institute for Breathing & Sleep, Department of Respiratory & Sleep Medicine, Austin Health, Victoria, Australia.
Study Objectives:
Drowsiness is a major risk factor for motor vehicle and occupational accidents. Real-time objective indicators of drowsiness could potentially identify drowsy individuals with the goal of intervening before an accident occurs. Several ocular measures are promising objective indicators of drowsiness; however, there is a lack of studies evaluating their accuracy for detecting behavioral impairment due to drowsiness in real time.
Methods:
In this study, eye movement parameters were measured during vigilance tasks following restricted sleep and in a rested state (n = 33 participants) at three testing points (n = 71 data points) to compare ocular measures to a gold standard measure of drowsiness (OSLER). The utility of these parameters for detecting drowsiness-related errors was evaluated using receiver operating characteristic curves (ROC) (adjusted by clustering for participant) and identification of optimal cutoff levels for identifying frequent drowsiness-related errors (4 missed signals in a minute using OSLER). Their accuracy was tested for detecting increasing frequencies of behavioral lapses on a different task (psychomotor vigilance task [PVT]).
Results:
Ocular variables which measured the average duration of eyelid closure (inter-event duration [IED]) and the ratio of the amplitude to velocity of eyelid closure were reliable indicators of frequent errors (area under the curve for ROC of 0.73 to 0.83, p < 0.05). IED produced a sensitivity and specificity of 71% and 88% for detecting ≥ 3 lapses (PVT) in a minute and 100% and 86% for ≥ 5 lapses. A composite measure of several eye movement characteristics (Johns Drowsiness Scale) provided sensitivities of 77% and 100% for detecting 3 and ≥ 5 lapses in a minute, with specificities of 85% and 83%, respectively.
Conclusions:
Ocular measures, particularly those measuring the average duration of episodes of eye closure are promising real-time indicators of drowsiness.