Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Beyond the LUMIR challenge: The pathway to foundational registration models.

Medical image analysis·2026
Same author

DSHARP: Deep Incompressible Motion Estimation with Sinusoidal-transformed Harmonic Phase for Tagged MRI.

IEEE transactions on medical imaging·2026
Same author

A Severity-Agnostic Atrophy Pattern in Spinocerebellar Ataxia Type 3: Volumetrics from ENIGMA-Ataxia.

Movement disorders : official journal of the Movement Disorder Society·2026
Same author

Proteomic Age Acceleration in Multiple Sclerosis Precedes Symptom Onset and Associates with Severity.

medRxiv : the preprint server for health sciences·2026
Same author

Imitation learning for supervised autonomous tumor resection in central airway obstruction.

International journal of computer assisted radiology and surgery·2026
Same author

Late Triggering in Tagged Magnetic Resonance Imaging for in vivo Characterization of Brain Biomechanics During Head Rotation.

Journal of biomechanical engineering·2026
Same journal

AVA: Automated Viewability Analysis for Ureteroscopic Intrarenal Surgery.

Proceedings of SPIE--the International Society for Optical Engineering·2026
Same journal

Kidney Endoscopy Video to Preoperative CT Alignment for Depth Estimation.

Proceedings of SPIE--the International Society for Optical Engineering·2026
Same journal

Deep learning‑based cell type prediction in lung tissue from brightfield histology using CODEX-derived labels.

Proceedings of SPIE--the International Society for Optical Engineering·2026
Same journal

Reconstructing physiological signals from fMRI across the adult lifespan.

Proceedings of SPIE--the International Society for Optical Engineering·2026
Same journal

Axially Swept Light-Sheet Microscopy using scattering and fluorescence contrast mechanisms.

Proceedings of SPIE--the International Society for Optical Engineering·2026
Same journal

Analytic Bounds on GAMLSS Model Variability of Normative White Matter Brain Charts.

Proceedings of SPIE--the International Society for Optical Engineering·2026
See all related articles

Related Experiment Video

Updated: May 4, 2026

Dynamic Lung Tumor Tracking for Stereotactic Ablative Body Radiation Therapy
08:17

Dynamic Lung Tumor Tracking for Stereotactic Ablative Body Radiation Therapy

Published on: June 7, 2015

15.2K

A Dynamic Dosimetry System for Prostate Brachytherapy.

Nathanael Kuo1, Ehsan Dehghan2, Anton Deguet3

  • 1Dept. of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, USA.

Proceedings of Spie--The International Society for Optical Engineering
|January 7, 2014
PubMed
Summary
This summary is machine-generated.

Dynamic dosimetry for prostate cancer treatment is now possible using standard ultrasound and C-arm imaging with a simple fiducial marker. This accessible system accurately computes dose, improving patient care with minimal training.

Keywords:
dynamic dosimetrymobile non-isocentric C-armprostate brachytherapytransrectal ultrasound

More Related Videos

A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
09:49

A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods

Published on: April 24, 2020

9.1K
Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
08:34

Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies

Published on: February 6, 2019

20.6K

Related Experiment Videos

Last Updated: May 4, 2026

Dynamic Lung Tumor Tracking for Stereotactic Ablative Body Radiation Therapy
08:17

Dynamic Lung Tumor Tracking for Stereotactic Ablative Body Radiation Therapy

Published on: June 7, 2015

15.2K
A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
09:49

A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods

Published on: April 24, 2020

9.1K
Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
08:34

Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies

Published on: February 6, 2019

20.6K

Area of Science:

  • Medical Physics
  • Oncology
  • Medical Imaging

Background:

  • Permanent prostate brachytherapy lacks dynamic dosimetry tools, leading to preventable issues in patient care.
  • Accurate real-time dose assessment is crucial for optimizing treatment outcomes in prostate cancer management.

Purpose of the Study:

  • To develop and validate an accessible dynamic dosimetry system for permanent prostate brachytherapy.
  • To address the need for readily adoptable tools that improve prostate cancer patient care.

Main Methods:

  • Utilized ultrasound scanner and mobile non-isocentric C-arm with a marker-based fiducial.
  • Developed robust algorithms for seed segmentation, fiducial detection, seed reconstruction, and image registration.
  • Validated the system on a study involving 25 prostate cancer patients.

Main Results:

  • Demonstrated the feasibility of dynamic dosimetry using accessible hardware.
  • Achieved accurate dose computation with minimal manual intervention.
  • System validation showed excellent performance in a clinical setting.

Conclusions:

  • The proposed system enables dynamic dosimetry in permanent prostate brachytherapy using readily available equipment.
  • The system's ease of use and accuracy show significant promise for widespread clinical adoption.
  • This advancement can lead to improved patient care and treatment efficacy in prostate cancer brachytherapy.