Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences

Inductively coupled plasma–mass spectrometry (ICP–MS) is a highly selective and sensitive technique for accurate elemental analysis. Though the analysis of ICP–MS mass spectra is comparatively straightforward, it is affected by spectroscopic and non-spectroscopic interferences. Spectroscopic interferences arise when the plasma contains ionic species with an m/z value the same as the analyte ion. Spectroscopic interference can be categorized as isobaric, polyatomic ions, and...
1.7K
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview01:19

Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview

In inductively coupled plasma–mass spectrometry (ICP–MS), an inductively coupled plasma (ICP) torch is used as an atomizer and ionizer. Solid samples are dissolved and volatilized before being introduced into the high-temperature argon plasma, while solution samples are nebulized and passed through the high-temperature argon plasma. Plasma dissociates the analytes and ionizes their component atoms to form a mixture of positive ions and molecular species. The positive ions are then...
2.7K
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle01:19

Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle

Inductively coupled plasma (ICP) is the most widely used plasma source in atomic emission spectroscopy (AES), also known as Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES). The ICP source, or torch, consists of three concentric quartz tubes with argon gas flowing through them. A spark from a Tesla coil initiates the ionization of argon, generating a high-temperature plasma.
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
2.4K
Pharmacokinetic–Pharmacodynamic Relationship: Problems01:24

Pharmacokinetic–Pharmacodynamic Relationship: Problems

The empirical approach to drug therapy optimization relies on correlating pharmacological response with administered dosage. Such an approach can be costly, time-consuming, and often yields poor correlation due to variables like formulation factors and drug elimination characteristics. A more precise approach correlates response with plasma drug concentration or the amount of drug in the body, rather than dosage. This is achieved through pharmacokinetic-pharmacodynamic (PK/PD) modeling, which...
127
Drug Concentrations: Measurements01:23

Drug Concentrations: Measurements

Drug concentration is the quantity of a drug present in a biological sample. Measuring drug amounts in biological samples allows the clinician to understand how a drug is absorbed, distributed, metabolized, and excreted. Samples can be obtained through invasive or non-invasive methods. Invasive techniques involve surgical or parenteral interventions to gather blood, cerebrospinal fluid, or tissue biopsy. Conversely, non-invasive approaches provide samples like urine, feces, and saliva.
Plasma...
1.6K
Effect of Hepatic Disease on Pharmacokinetics: Pathophysiologic Assessment and Liver Function Test01:22

Effect of Hepatic Disease on Pharmacokinetics: Pathophysiologic Assessment and Liver Function Test

In clinical practice, the direct measurement of hepatic blood flow to evaluate liver function presents significant challenges due to the intricate and specialized nature of the necessary techniques. Consequently, healthcare professionals often rely on empirical estimates derived from thorough patient examinations and liver function tests to gauge liver health. Among the tools at their disposal, the Child–Pugh and MELD scoring systems stand out for their ability to categorize and assess...
271