The effect of central shielding in the dose reporting for cervical cancer in EQD2 era
Ekkasit Tharavichitkul1, Somsak Wanwilairat1, Anirut Watcharawipha1
1The Division of Therapeutic Radiology and Oncology, Department of Radiology, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand.
Purpose:
To evaluate the cumulative dose at point A for three and four centimeters central shielding.
Material And Methods:
The plans of external beam radiotherapy plus conventional intracavitary brachytherapy were performed. Three or four centimeters central shieldings (after 44 Gy) were applied to the standard whole pelvis irradiation. Additional intracavitary brachytherapy 4 × 7 Gy at point A was prescribed, and the cumulative dose in EQD2 (α/β = 10) of 3 cm and 4 cm central shielding were evaluated.
Results:
The cumulative dose at point A in EQD2 (α/β = 10) of 3 cm central shielding were 95.7 Gy for AR and 95.5 Gy for AL, while the cumulative dose at point As in EQD2 (α/β = 10) of 4 cm central shielding were 90.8 Gy for AR and 91.2 Gy for AL.
Conclusions:
The 3 cm central shielding caused higher cumulative dose (in terms of EQD2 [α/β = 10]) than 4 cm central shielding.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
07:31Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator
Published on: May 9, 2014
Related Concept Videos
Diamagnetic Shielding of Nuclei: Local Diamagnetic Current
Biological Effects of Radiation
Nuclear Power
Nuclear Fuels
Nuclear fuel consists of a fissile isotope, such as uranium-235, which must be present in sufficient quantity to provide a...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...