Tandem differential mobility spectrometry in purified air for high-speed selective vapor detection
Marlen R Menlyadiev1, Gary A Eiceman
1Department of Chemistry and Biochemistry, New Mexico State University , Las Cruces, New Mexico, 88003, United States.
Abstract:
A tandem ion mobility instrument based on differential mobility spectrometry (DMS) was used to demonstrate selectivity in response through differences in field dependence of mobility for ions in purified air at ambient pressure. The concept of chemical selectivity solely from characteristic dispersion curves or from field dependence of ion mobility was experimentally demonstrated in three steps with mixtures of increasing complexity. In a mixture of four alcohols with carbon numbers four and below, distinct pairs of separation voltage and compensation voltage, applied to the first and second DMS stages, permitted isolation of ions from individual substances without detectable levels of other substances. In a three-component mixture of a ketone, alcohol, and organophosphorus compound, the same level of ion isolation was observed using specific and characteristic separation and compensation voltages on each DMS stage. In the last experiment, the isolation of product ions of individual substances from a mixture of 23 volatile organic compounds from four chemical groups was incomplete though the improvement in the ratio of analyte signal to chemical noise was calculated as 31 for DMMP and 106 for 1-hexanol. These findings demonstrate that chemical information available in dispersion curves can be accessed in response times below 100 ms through a tandem DMS measurement.
More Related Videos
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
08:23Real-time Breath Analysis by Using Secondary Nanoelectrospray Ionization Coupled to High Resolution Mass Spectrometry
Published on: March 9, 2018
Related Concept Videos
Tandem Mass Spectrometry
Gas Chromatography: Types of Detectors-II
High-Performance Liquid Chromatography: Types of Detectors
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...