Introduction:
Our objective was to assess the intraexaminer and interexaminer reliabilities of upper airway linear, area, and volumetric measurements in cone-beam computed tomography.
Methods:
Cone-beam computed tomography scans of 12 subjects were randomly selected from a pool of 132 orthodontic patients. An undergraduate student, an orthodontist, and a dental radiologist independently made linear, area, and volumetric measurements. Linear anteroposterior and transversal measurements, cross-sectional area, sagittal area, minimum axial area, and volume measurements were made. The intraclass correlation coefficient (ICC) was used to assess intraexaminer and interexaminer reliabilities, and measurement errors were assessed. Agreement was further assessed with the Bland-Altman method and 95% limits of agreement.
Results:
Overall, the ICC values indicated good reliability for the measurements assessed. The ICC values were greater than 0.9 (excellent) for 93% of intraexaminer and 73% of interexaminer assessments. Transversal width measurements and cross-sectional area at the level of the vallecula, however, had only moderate reliability (minimum ICC, 0.63), large 95% limits of agreement, and the greatest mean measurement errors (as high as 16% and 13% of the mean measurements, respectively). Linear anteroposterior measurements; cross-sectional areas at the levels of the palatal plane, soft palate, and tongue; and sagittal area and volume were reliable measurements, with a minimum ICC of 0.93 and more restricted limits of agreement.
Conclusions:
Based on these results, airway assessments by examiners with different backgrounds might have reliable anteroposterior linear measurements; cross-sectional areas at the levels of the palatal plane, soft palate, and tongue; and sagittal area and volume. The unreliable measurements were linear width, cross-sectional area at the level of the vallecula, and minimum axial area.