Related Experiment Video
Updated: May 3, 2026

Author Spotlight: Non-Invasive Imaging of Complex Bio-Structures Using Polarization-Sensitive Two-Photon Microscopy
Published on: September 8, 2023
An analytical formalism to calculate phantom scatter factors for flattening filter free (FFF) mode photon beams
Heeteak Chung1, Karl L Prado, Byong Yong Yi
1Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, MD 21201, USA.
Abstract:
Phantom Scatter Factors, Sp in the Khan formalism (Khan et al 1980 J. Radiat. Oncol. Biol. Phys. 6 745-51) describe medium-induced changes in photon-beam intensity as a function of size of the beam. According to the British Journal of Radiology, Supplement 25, megavoltage phantom scatter factors are invariant as a function of photon-beam energy. However, during the commissioning of an accelerator with flattening filter free (FFF) photon beams (Varian TrueBeam(TM) 6-MV FFF and 10-MV FFF), differences were noted in phantom scatter between the filtered beams and FFF-mode beams. The purpose of this work was to evaluate this difference and provide an analytical formalism to explain the phantom scatter differences between FFF-mode and the filtered mode. An analytical formalism was devised to demonstrate the source of phantom scatter differences between the filtered and the FFF-mode beams. The reason for the differences in the phantom scatter factors between the filtered and the FFF-mode beams is hypothesized to be the non-uniform beam profiles of the FFF-mode beams. The analytical formalism proposed here is based on this idea, taking the product of the filtered phantom scatter factors and the ratio of the off-axis ratio between the FFF-mode and the filtered beams. All measurements were performed using a Varian TrueBeam(TM) linear accelerator with photon energies of 6-MV and 10-MV in both filtered and FFF-modes. For all measurements, a PTW Farmer type chamber and a Scanditronix CC04 cylindrical ionization were used. The in-water measurements were made at depth dose maximum and 100 cm source-to-axis distance. The in-air measurements were done at 100 cm source-to-axis distance with appropriate build-up cap. From these measurements, the phantom scatter factors were derived for the filtered beams and the FFF-mode beams for both energies to be evaluated against the phantoms scatter factors calculated using the proposed algorithm. For 6-MV, the difference between the measured and the calculated FFF-mode phantom scatter factors ranged from -0.34% to 0.73%. The average per cent difference was -0.17% (1σ = 0.25%). For 10-MV, the difference ranged from -0.19% to 0.24%. The average per cent difference was -0.17% (1σ = 0.13%). An analytical formalism was presented to calculate the phantom scatter factors for FFF-mode beams using filtered phantom scatter factors as a basis. The overall differences between measurements and calculations were within ± 0.5% for 6-MV and ± 0.25% for 10-MV.

