Artifacts in musculoskeletal MR imaging

Dinesh R Singh1, Michael S M Chin1, Wilfred C G Peh1

  • 1Department of Diagnostic Radiology, Khoo Teck Puat Hospital, Alexandra Health, Singapore, Republic of Singapore.

Insights

Magnetic resonance (MR) imaging artifacts can degrade image quality and mimic pathologies, especially with higher field strengths and metallic implants. Recognizing and correcting these artifacts is crucial for accurate musculoskeletal diagnosis.

Area of Science:

  • Radiology
  • Medical Imaging
  • Biomedical Engineering

Background:

  • Magnetic resonance (MR) imaging is vital for musculoskeletal system evaluation, including spine, joints, and soft tissues.
  • Image quality is susceptible to artifacts that can mimic or obscure pathologies.
  • Artifacts are increasingly significant with higher magnetic field strengths and in patients with metallic implants.

Purpose of the Study:

  • To review common and important artifacts encountered in musculoskeletal MR imaging.
  • To highlight artifacts that are more prevalent with advanced imaging techniques and in specific patient populations.
  • To emphasize the importance of artifact recognition for accurate image interpretation.

Main Methods:

  • Review of common MR imaging artifacts relevant to musculoskeletal applications.
  • Discussion of artifact origins, including patient motion, physiological processes, protocol errors, and material properties.
  • Focus on susceptibility artifacts and the magic angle phenomenon.

Main Results:

  • Artifacts can arise from patient motion, physiological pulsations (cardiac, vascular), and protocol errors (saturation, wraparound, truncation, shading, partial volume averaging, RF interference).
  • Susceptibility artifacts are critical at interfaces with differing magnetic susceptibilities, particularly with metallic implants.
  • The magic angle phenomenon is a specific artifact in musculoskeletal MR imaging.

Conclusions:

  • Artifacts are an inherent challenge in MR imaging, impacting diagnostic accuracy.
  • Understanding artifact generation is essential for optimizing imaging protocols and interpretation.
  • Correct identification and management of artifacts are critical to avoid diagnostic errors in musculoskeletal imaging.

Related Concept Videos

Magnetic Resonance Imaging01:24

Magnetic Resonance Imaging

Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...
7.6K
Imaging Studies I: CT and MRI01:14

Imaging Studies I: CT and MRI

Introduction: MRI and CT scans are crucial advancements in medical imaging techniques, playing a vital role in diagnosing conditions related to the gastrointestinal (GI) system. Each scan serves distinct purposes, targets specific areas, and requires unique nursing duties.
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
1.3K
Ultrasonography01:17

Ultrasonography

Ultrasonography is an imaging technique that uses high-frequency sound waves to visualize the body's internal structures. It is a non-invasive and safe procedure that does not involve the use of ionizing radiation, making it widely used in various medical fields. Ultrasonography is used to study heart function, blood flow in the neck or extremities, certain conditions such as gallbladder disease, and fetal growth and development.
During an ultrasonography procedure, a handheld device called...
6.5K