The effect of bolus volume on hyoid kinematics in healthy swallowing
Related Experiment Video
Updated: Apr 30, 2026

Coordinate Mapping of Hyolaryngeal Mechanics in Swallowing
Published on: May 6, 2014
Ahmed Nagy1, Sonja M Molfenter2, Melanie Péladeau-Pigeon3
1Toronto Rehabilitation Institute, University Health Network, Toronto, ON, Canada M5G 2A2 ; University of Fayoum, Fayoum 63514, Egypt.
Abstract:
Hyoid movement in swallowing is biomechanically linked to closure of the laryngeal vestibule for airway protection and to opening of the upper esophageal sphincter. Studies suggest that the range of hyoid movement is highly variable in the healthy population. However, other aspects of hyoid movement such as velocity remain relatively unexplored. In this study, we analyze data from a sample of 20 healthy young participants (10 male) to determine whether hyoid movement distance, duration, velocity, and peak velocity vary systematically with increases in thin liquid bolus volume from 5 to 20 mL. The temporal correspondence between peak hyoid velocity and laryngeal vestibule closure was also examined. The results show that maximum hyoid position and peak velocity increase significantly for 20 mL bolus volumes compared to smaller volumes, and that the timing of peak velocity is closely linked to achieving laryngeal vestibule closure. This suggests that generating hyoid movements with increased power is a strategy for handling larger volumes.
More Related Videos
08:32Adapting Human Videofluoroscopic Swallow Study Methods to Detect and Characterize Dysphagia in Murine Disease Models
Published on: March 1, 2015
07:45Minimally Invasive Murine Laryngoscopy for Close-Up Imaging of Laryngeal Motion During Breathing and Swallowing
Published on: December 1, 2023
Related Concept Videos
The Hyoid Bone
Upper GI Series: Barium Swallow
Purpose and Procedure
Patients undergoing this procedure ingest a liquid containing barium sulfate with a chalky...
Deglutition
Swallowing can be divided into three stages: the voluntary phase, the pharyngeal phase, and the esophageal phase. Although the...
Two-Compartment Open Model: IV Bolus Administration
The disparity between drug input and the sum of drug transfer rates between...
One-Compartment Open Model for IV Bolus Administration: General Considerations
The drug's presence in the body is defined by an equation representing the difference between the rates of drug entry and exit. Key parameters—elimination rate constant,...
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...