Related Experiment Video
Updated: Apr 30, 2026

An Improved Mechanical Testing Method to Assess Bone-implant Anchorage
Published on: February 10, 2014
The effect of different implant-abutment connections on screw joint stability
Konstantinos X Michalakis1, Pasquale Lino Calvani, Sinan Muftu
11 Division of Graduate and Postgraduate Prosthodontics, Tufts University School of Dental Medicine, Boston, Mass.
Abstract:
Dental implants with an internal connection have been designed to establish a better stress distribution when lateral external forces act on the prosthesis and minimize the forces transmitted to the fastening screw. In the present study, 10 externally and 10 internally hexed implants were tested with a compressive force applied with an Instron Universal machine. Four cycles of loading-unloading were applied to each specimen to achieve displacements of 0.5, 1, 2, and 2.5 mm. The mean loads for the first cycle were 256.70 N for the external connection and 256 N for the internal connection implants. The independent t test did not reveal any significant differences among the 2 tested groups (P = .780). For the second cycle, the mean loads needed for a displacement of 1 mm were 818.19 N and 780.20 N for the external connection and the internal connection implants, respectively. The independent t test revealed significant differences among the 2 tested groups (P < .001). In the third cycle, the mean load values for a 2-mm displacement were 1394.10 N and 1225.00 N. The independent t test revealed significant differences among the 2 tested groups (P < .001). The mean loads for the fourth cycle were 1488.00 N for the external connection and 1029.00 N for the internal connection implants. These loads were required for a displacement of 2.5 mm. The independent t test revealed significant differences among the 2 tested groups (P < .001). The results of this in vitro study suggest that the internal connection design of the examined implant system could not prevent screw loosening during overloading. No implant or prosthesis failure was noticed in either group.
Related Concept Videos
Frictional Forces on Screws
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Wood Fasteners
Nails are the most common fasteners, consisting of sharp-pointed metal pins that are driven into wood using a hammer or a mechanical nail gun. They come in a variety of diameters, heads, and lengths. Nailing techniques include...
Method of Joints: Problem Solving II
Bonding and Strength of Aggregate

