In situ Compressive Loading and Correlative Noninvasive Imaging of the Bone-periodontal Ligament-tooth Fibrous Joint
Published on: March 7, 2014
Dynamic shear modulus in torsion of human dentin and enamel
Abstract:
The dynamic shear moduli of human dentin and enamel were measured using a torsion pendulum over a temperature range from 23 to 150 degrees C. For dentin, the shear modulus slightly increased for temperatures near 50 to 100 degrees C, which was caused by a loss of free water. The peak in the loss tangent was observed near 75 degrees C. The shear moduli at 37 degrees C for sixty coronal dentin specimens ranged from 5.77 X 10(10) to 1.16 X 10(11) dyn/cm2. For enamel, the shear modulus and the loss tangent were markedly stable and independent of the temperature. The shear moduli at 37 degrees C for forty specimens ranged from 2.35 X 10(11) to 4.48 X 10(11) dyn/cm2. Enamel had a modulus which was approximately three to five times higher, and a lower loss tangent than those of dentin. For both dentin and enamel, there were no significant correlations between the values of the shear modulus and sex, age or tooth type.
More Related Videos
Related Concept Videos
Strain and Elastic Modulus
Problem Solving on Stress and Strain
Shearing Strain
Relation between Poisson's ratio, Modulus of Elasticity and Modulus of Rigidity
Thin-Walled Hollow Shafts
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by a...