Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Association between Food Insecurity and Overweight: a Systematic Review based on Intersectionality of Gender and Race/Color.

Nutrition reviews·2025
Same author

Performance of the Implant Disease Risk Assessment in Predicting Peri-Implantitis: A Retrospective Study.

Clinical oral implants research·2024
Same author

Preloading peri-implant crestal bone loss: A retrospective study of incidence and related factors.

Journal of periodontology·2024
Same author

Effect of a chlorhexidine-encapsulated nanotube modified pit-and-fissure sealant on oral biofilm.

Dental materials journal·2021
Same author

Low-temperature plasma on peri-implant-related biofilm and gingival tissue.

Journal of periodontology·2018
Same author

Quality of life related to complete denture.

Acta odontologica latinoamericana : AOL·2018

Related Experiment Video

Updated: Apr 28, 2026

Effects of Mechanical Methods Used in Peri-implantitis Treatment on Implant Surface Decontamination and Roughness
06:36

Effects of Mechanical Methods Used in Peri-implantitis Treatment on Implant Surface Decontamination and Roughness

Published on: March 14, 2025

1.0K

Technical complications with implant-supported dental prostheses.

Patrícia S Calderon1, Poliana M C Dantas, Sheyla C L Montenegro

  • 1Department of Dentistry, Federal University of Rio Grande do Norte.

Journal of Oral Science
|June 17, 2014
PubMed
Summary

This study analyzed technical complications in implant-supported prostheses. Most frequent issues included resin loss and overdenture retention loss, highlighting the need for improved protocols in dental prosthetic rehabilitation.

More Related Videos

Oral Biofilm Formation on Different Materials for Dental Implants
11:19

Oral Biofilm Formation on Different Materials for Dental Implants

Published on: June 24, 2018

11.0K
Bioelectric Analyses of an Osseointegrated Intelligent Implant Design System for Amputees
14:31

Bioelectric Analyses of an Osseointegrated Intelligent Implant Design System for Amputees

Published on: July 15, 2009

15.7K

Related Experiment Videos

Last Updated: Apr 28, 2026

Effects of Mechanical Methods Used in Peri-implantitis Treatment on Implant Surface Decontamination and Roughness
06:36

Effects of Mechanical Methods Used in Peri-implantitis Treatment on Implant Surface Decontamination and Roughness

Published on: March 14, 2025

1.0K
Oral Biofilm Formation on Different Materials for Dental Implants
11:19

Oral Biofilm Formation on Different Materials for Dental Implants

Published on: June 24, 2018

11.0K
Bioelectric Analyses of an Osseointegrated Intelligent Implant Design System for Amputees
14:31

Bioelectric Analyses of an Osseointegrated Intelligent Implant Design System for Amputees

Published on: July 15, 2009

15.7K

Area of Science:

  • Dentistry
  • Biomaterials Science
  • Prosthodontics

Background:

  • Dental prosthetic rehabilitation is crucial for restoring function and aesthetics.
  • Understanding complications of implant-supported prostheses is essential for long-term success.
  • Previous studies have indicated varying complication rates, necessitating further investigation.

Purpose of the Study:

  • To evaluate the frequency and types of technical complications associated with implant-supported prostheses.
  • To identify factors contributing to these complications.
  • To provide evidence-based recommendations for minimizing complications in dental prosthetic rehabilitation.

Main Methods:

  • A retrospective, one-time snapshot study design was employed.
  • Data were collected from 153 patients with a total of 509 implants.
  • Prosthetic conditions were assessed through comprehensive clinical and radiographic examinations.

Main Results:

  • The most frequent technical complications were loss of resin covering the screw (23.8%), loss of overdenture retention (18.6%), and resin fractures (12.4%).
  • Screw-related complications like fracture (0.2%), loss (0.4%), and loosening (3.3%) were infrequent.
  • A significant frequency of prosthesis-abutment misfit (25.4%) was observed, particularly with cemented prostheses (P < 0.001).

Conclusions:

  • Technical complications in implant-supported prostheses are common, with resin-related issues and misfit being prevalent.
  • Establishing robust protocols from diagnosis through follow-up, including meticulous technical procedures and radiographic evaluation, is vital.