Related Experiment Video
Updated: Apr 27, 2026

In Vitro Method to Control Concentrations of Halogenated Gases in Cultured Alveolar Epithelial Cells
Published on: October 23, 2018
Feasibility and practical considerations for heating and humidifying gases during newborn stabilisation: an in vitro
Louise S Owen1, Jennifer A Dawson, Robin Middleburgh
1The Royal Women's Hospital, Melbourne, Vic., Australia.
Background:
Gases for respiratory support at birth are typically 'cold and dry', which may increase the risk of hypothermia and lung injury.
Objectives:
To determine the feasibility of using heated humidification from birth.
Method:
A humidifier targeting 37°C, a manual-fill chamber and a Neopuff Infant T-piece resuscitator and circuit were attached to a face mask and a manikin. Recordings using 20 ml H2O for humidification and a flow of 10 l/min were undertaken. Temperature and relative humidity (RH) were recorded. Additional recordings were made, each with one alteration to baseline (50 ml H2O for humidification, auto-fill chamber, a flow of 8 l/min, addition of circuit extension piece, warmed humidification H2O, increased ambient temperature and targeting 31°C). The duration of heated humidification and the response to disconnecting the power were investigated.
Results:
The baseline circuit achieved 95% RH and 31°C in 3 min, >99% RH in 7 min and ≥35°C in 9 min. No circuit alterations resulted in faster gas conditioning. The extended length circuit and targeting 31°C reduced the maximum temperature achieved. A flow of 8 l/min resulted in slower heating and humidification. The baseline circuit delivered heated humidification for 39 min. Without power, the temperature and humidity fell below international standards in 3 min.
Conclusion:
Rapid gas conditioning for newborn stabilisation is feasible using the experimental set-up, ≥20 ml H2O and a flow of 10 l/min. The circuit could be used immediately once switched on. Without power, conditioning is quickly lost. Investigation of the clinical effects of gas conditioning is warranted.
More Related Videos
05:45Delivery of In Vivo Acute Intermittent Hypoxia in Neonatal Rodents to Prime Subventricular Zone-derived Neural Progenitor Cell Cultures
Published on: November 2, 2015
09:36Halogenated Agent Delivery in Porcine Model of Acute Respiratory Distress Syndrome via an Intensive Care Unit Type Device
Published on: September 24, 2020
Related Concept Videos
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Physical Principles Governing Gas Exchange
Gas Laws Governing Respiration
The behavior of gases is guided by Dalton's Law of partial pressures and Henry's Law.
Dalton's Law asserts that the total...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes: