Subject-specific estimation of central aortic blood pressure via system identification: preliminary in-human
Nima Fazeli1, Chang-Sei Kim, Mohammad Rashedi
1Mechanical Engineering, University of Maryland, College Park, USA.
Abstract:
This paper demonstrates preliminary in-human validity of a novel subject-specific approach to estimation of central aortic blood pressure (CABP) from peripheral circulatory waveforms. In this "Individualized Transfer Function" (ITF) approach, CABP is estimated in two steps. First, the circulatory dynamics of the cardiovascular system are determined via model-based system identification, in which an arterial tree model is characterized based on the circulatory waveform signals measured at the body's extremity locations. Second, CABP waveform is estimated by de-convolving peripheral circulatory waveforms from the arterial tree model. The validity of the ITF approach was demonstrated using experimental data collected from 13 cardiac surgery patients. Compared with the invasive peripheral blood pressure (BP) measurements, the ITF approach yielded significant reduction in errors associated with the estimation of CABP, including 1.9-2.6 mmHg (34-42 %) reduction in BP waveform errors (p < 0.05) as well as 5.8-9.1 mmHg (67-76 %) and 6.0-9.7 mmHg (78-85 %) reductions in systolic and pulse pressure (SP and PP) errors (p < 0.05). It also showed modest but significant improvement over the generalized transfer function approach, including 0.1 mmHg (2.6 %) reduction in BP waveform errors as well as 0.7 (20 %) and 5.0 mmHg (75 %) reductions in SP and PP errors (p < 0.05).
More Related Videos
11:26Assessing Cerebral Autoregulation via Oscillatory Lower Body Negative Pressure and Projection Pursuit Regression
Published on: December 10, 2014
06:51Development of an Algorithm to Perform a Comprehensive Study of Autonomic Dysreflexia in Animals with High Spinal Cord Injury Using a Telemetry Device
Published on: July 29, 2016
Related Concept Videos
Assessment of blood pressure in brachial artery(two-step method)
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure