Related Experiment Video
Updated: Apr 24, 2026

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease
Published on: December 18, 2016
Improving the spectral resolution and spectral fitting of (1) H MRSI data from human calf muscle by the SPREAD
Zhengchao Dong1, Yudong Zhang, Feng Liu
1Department of Psychiatry, Columbia University College of Physicians and Surgeons, New York, USA; New York State Psychiatric Institute, New York, USA.
Abstract:
Proton magnetic resonance spectroscopic imaging ((1) H MRSI) has been used for the in vivo measurement of intramyocellular lipids (IMCLs) in human calf muscle for almost two decades, but the low spectral resolution between extramyocellular lipids (EMCLs) and IMCLs, partially caused by the magnetic field inhomogeneity, has hindered the accuracy of spectral fitting. The purpose of this paper was to enhance the spectral resolution of (1) H MRSI data from human calf muscle using the SPREAD (spectral resolution amelioration by deconvolution) technique and to assess the influence of improved spectral resolution on the accuracy of spectral fitting and on in vivo measurement of IMCLs. We acquired MRI and (1) H MRSI data from calf muscles of three healthy volunteers. We reconstructed spectral lineshapes of the (1) H MRSI data based on field maps and used the lineshapes to deconvolve the measured MRS spectra, thereby eliminating the line broadening caused by field inhomogeneities and improving the spectral resolution of the (1) H MRSI data. We employed Monte Carlo (MC) simulations with 200 noise realizations to measure the variations of spectral fitting parameters and used an F-test to evaluate the significance of the differences of the variations between the spectra before SPREAD and after SPREAD. We also used Cramer-Rao lower bounds (CRLBs) to assess the improvements of spectral fitting after SPREAD. The use of SPREAD enhanced the separation between EMCL and IMCL peaks in (1) H MRSI spectra from human calf muscle. MC simulations and F-tests showed that the use of SPREAD significantly reduced the standard deviations of the estimated IMCL peak areas (p < 10(-8) ), and the CRLBs were strongly reduced (by ~37%).
More Related Videos
10:28Measuring Interactions of Globular and Filamentous Proteins by Nuclear Magnetic Resonance Spectroscopy NMR and Microscale Thermophoresis MST
Published on: November 2, 2018
08:0915N CPMG Relaxation Dispersion for the Investigation of Protein Conformational Dynamics on the µs-ms Timescale
Published on: April 19, 2021
Related Concept Videos
NMR Spectrometers: Resolution and Error Correction
High-Resolution Mass Spectrometry (HRMS)
2D NMR: Overview of Homonuclear Correlation Techniques
COSY90 is the standard two-dimensional (2D) COSY experiment that...
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
2D NMR: Homonuclear Correlation Spectroscopy (COSY)
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...