System efficiency of a tap transformer based grid connection topology applied on a direct driven generator for wind

Senad Apelfröjd1, Sandra Eriksson1

  • 1Swedish Center for Renewable Electric Energy Conversion, Division for Electricity, Uppsala University, Box 534, 751 21 Uppsala, Sweden.

Thescientificworldjournal
|September 27, 2014
PubMed

Related Concept Videos

Control of Power Flow01:30

Control of Power Flow

There are several methods to control power flow in power systems:
851
Generation of Three-Phase Voltage01:21

Generation of Three-Phase Voltage

A three-phase AC generator has a rotor with a rotating magnet placed within the stator mounted with the stationary three-phase winding to generate three-phase voltages via mutual induction. These windings are evenly distributed around the inner circumference of the stator and are arranged 120 electrical degrees apart. Three-phase stator windings consist of three separate coils or groups of coils, known as phases, each connected in Y (star) configuration or Delta configuration.
As the rotor...
1.0K
Transformers in Distribution System01:27

Transformers in Distribution System

Transformers in distribution systems can be broadly categorized into distribution substation transformers and other distribution transformers. They are crucial for stepping down high transmission voltages to levels suitable for distribution and end-user applications.
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
677
Turbine-Governor Control01:17

Turbine-Governor Control

Turbine-governor control is crucial for maintaining power system stability by balancing turbine mechanical power output with electrical load demand. This mechanism ensures that generator frequency and rotor speed are within acceptable limits during load variations. Turbine-generator units store kinetic energy due to their rotating masses; this energy is released to meet the load requirement when the load increases. The electrical torque of turbines rises to meet the demand, whereas the...
1.3K
Generator Voltage Control01:21

Generator Voltage Control

Generator voltage control is crucial for maintaining the stable operation of synchronous generators and wind turbines. In older models, a DC generator driven by the rotor delivers DC power to the rotor's field winding, and the power is transferred through slip rings and brushes. In the latest models, static or brushless exciters are used. Static exciters rectify AC power from the generator terminals and then transfer the DC power directly to the rotor. Brushless exciters, on the other hand, use...
866
Wind Turbine Machine Models01:24

Wind Turbine Machine Models

In the growing field of wind energy, incorporating wind turbine models into transient stability analysis is essential. Induction and synchronous machines are the primary models used, with induction machines being prevalent due to their simplicity and reliability.
Induction machines interact through the rotating magnetic field generated by the stator and the rotor. The key parameter is slip, which is the difference between synchronous speed and rotor speed relative to synchronous speed. Slip is...
772