Artificial neural network prediction of multilinear gradient retention in reversed-phase HPLC: comprehensive
Angelo Antonio D'Archivio1, Maria Anna Maggi, Fabrizio Ruggieri
1Dipartimento di Scienze Fisiche e Chimiche, Università degli Studi dell'Aquila, Via Vetoio, Coppito, 67010, L'Aquila, Italy, angeloantonio.darchivio@univaq.it.
Abstract:
A multilayer artificial neural network (ANN) is used to model the reversed-phase liquid chromatography retention times of 16 selected compounds, including purines, pyrimidines and nucleosides. The analysed data, taken from literature, were collected in acetonitrile-water eluents under the application of 16 different multilinear gradients. The parameters describing the gradient profile together with solute descriptors are considered as the independent variables of an ANN-based model providing the retention time as response. Categorical variables or, alternatively, a selected set of molecular descriptors of computational origin are adopted to represent the solutes. Network training, validation and testing are performed preliminarily using data of 12, 2 and 4 gradients, respectively and successively, to investigate model performance under more severe calibration conditions, with data of 9, 2 and 7 gradients. The proposed approach allows a quite accurate prediction of retention times of the target analytes in external multilinear gradients. Categorical variables can successfully represent the target solutes when the model is called to transfer retention data from calibration to external gradients. In particular, using a five-dimensional bit string to represent the analytes, mean errors on retention times are 2 and 3 % under the most and less favourable calibration conditions, respectively. A comparable performance is observed if the categorical variables are replaced by five molecular descriptors, selected by a genetic algorithm within a large set of structural variables of computational origin.
More Related Videos
06:50O-cresol Concentration Online Measurement Based On Near Infrared Spectroscopy Via Partial Least Square Regression
Published on: November 8, 2019
11:38Author Spotlight: Enhancing PSC-to-Functional Cell Differentiation Using ML Models Based on Live-Cell Bright-Field Imaging
Published on: October 4, 2024
Related Concept Videos
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Types of Detectors
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Instrumentation
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
End Point Prediction: Gran Plot
For potentiometric titration, the Gran plot is created by plotting...