An open-source and low-cost monitoring system for precision enology

Salvatore Filippo Di Gennaro1, Alessandro Matese2, Mirko Mancin3

  • 1Istituto di Biometeorologia (IBIMET-CNR), Consiglio Nazionale delle Ricerche, Via G. Caproni 8, Firenze 50145, Italy. f.digennaro@ibimet.cnr.it.

Related Concept Videos

Bioreactor Controls-I01:28

Bioreactor Controls-I

Maintaining optimal conditions within fermenters is essential for maximizing microbial productivity and ensuring process efficiency. This lesson focuses on key parameters—temperature, foam, pH, carbon dioxide, oxygen, and pressure—and their precise measurement and control strategies in fermentation systems.Temperature ControlTemperature regulation is critical due to the exothermic nature of many fermentation processes. In small laboratory fermenters, temperature is commonly...
81
Automated Microbial Diagnostics01:24

Automated Microbial Diagnostics

Automated diagnostic analyzers have transformed clinical microbiology by providing rapid and reliable methods for pathogen identification and antibiotic susceptibility testing. Among these systems, the Vitek 2 is widely used because it automates the traditionally labor-intensive processes of microbial identification (ID) and antibiotic susceptibility testing (AST), delivering standardized and timely results that are essential for effective patient care.Microbial Identification with ID CardsThe...
59
Bioreactor Design and Operational System01:29

Bioreactor Design and Operational System

Bioreactors are engineered vessels designed to cultivate microorganisms under controlled conditions for industrial bioprocessing. They maintain sterility and allow precise regulation of pH, temperature, oxygen, and nutrient levels to optimize microbial growth and metabolite production. Bioreactors range from small laboratory units of 1 liter to industrial systems holding up to 500,000 liters, though only about 75% of their volume is actively used for fermentation. The remaining headspace...
169
Testing Water Quality01:14

Testing Water Quality

When the quality of water for concrete preparation is uncertain, its impact on the setting time of cement and compressive strength of mortar is assessed by comparison with de-ionized or distilled water benchmarks. American Society for Testing and Materials (ASTM) C1602 requires the setting times to be within 90 minutes of the control, British Standard (BS) 3146:1980 allows a 30-minute variance in the initial setting, while British Standards European Norm (BS EN) 1008 specifies initial setting...
595
Microbial Biosensors01:17

Microbial Biosensors

Microbial biosensors are analytical devices that utilize living microbes to detect specific substances through measurable signals. These devices consist of two main components: biosensing organisms and signal-transducing elements. Biosensing organisms, such as Escherichia coli or Saccharomyces cerevisiae, are typically housed in multiwell plates connected to transducers, enabling rapid, real-time detection of target analytes.Signal Generation MechanismWhen a target analyte—such as...
71
Precipitation Titration: Endpoint Detection Methods01:19

Precipitation Titration: Endpoint Detection Methods

In argentometric precipitation titrations, endpoints can be detected visually by the Mohr, Volhard, and Fajans methods. In the Mohr method, adding a soluble chromate indicator gives an initial yellow color to the analyte solution. As the titrant is added, the first excess of silver ions forms a red silver chromate precipitate, marking the endpoint. The solution pH should be maintained at about 8 by adding solid CaCO3.
In the Volhard method, a standard excess of AgNO3 is first added to the...
6.7K