Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Imaging Biological Samples with Optical Microscopy01:18

Imaging Biological Samples with Optical Microscopy

12.3K
Optical microscopy uses optic principles to provide detailed images of samples. Antonie van Leeuwenhoek designed the first compound optical microscope in the 17th century to visualize blood cells, bacteria, and yeast cells. In 1830, Joseph Jackson Lister created an essentially modern light microscope. The 20th century saw the development of microscopes with enhanced magnification and resolution.
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
12.3K
Computed Tomography01:10

Computed Tomography

9.7K
Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
9.7K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Clinical validation of a Novel Robotic Device for MR-Guided Prostate Biopsy: Initial Patient Experience.

Journal of medical robotics research·2026
Same author

AI-Assisted OCT Imaging for Core Needle Biopsy Guidance: The 1st in Humans Study.

Diagnostics (Basel, Switzerland)·2026
Same author

Method for retrospective, respiratory-gated, anatomical optical coherence tomography for airway wall elastography.

Journal of biomedical optics·2025
Same author

<i>In vivo</i> assessment of airway wall compliance during inhalation injury response using anatomical optical coherence elastography.

Journal of biomedical optics·2025
Same author

Characterizing Vascular Wall and Lumen Caliber in Eyes with Diabetic Retinopathy Based on Adaptive Optics Scanning Laser Ophthalmoscopy.

Diagnostics (Basel, Switzerland)·2024
Same author

Unraveling the Long-term Natural History of Branch Duct Intraductal Papillary Mucinous Neoplasm: Beyond 10 years.

Annals of surgery·2024
Same journal

Gaussian-modulated continuous-variable quantum key distribution over 60 km fiber using an integrated silicon photonic receiver.

Optics letters·2026
Same journal

E2E-OCT: end-to-end joint learning model using optical coherence tomography images for vocal cord leukoplakia diagnosis.

Optics letters·2026
Same journal

Holographic generation of panoramic 3D scenes by concave ellipsoidal mirror reflection.

Optics letters·2026
Same journal

Dual-pilot phase recovery with pair-wise maximum-ratio combining for coherent PONs.

Optics letters·2026
Same journal

Mapping the whispering gallery modes of a CaF<sub>2</sub> disk resonator with half-tapered fibers to estimate the fundamental mode volume.

Optics letters·2026
Same journal

Quantitative estimation of deep-subwavelength scale via dark-field scattering axial energy concentration decay profiles.

Optics letters·2026
See all related articles

Related Experiment Video

Updated: Apr 19, 2026

Multimodal Volumetric Retinal Imaging by Oblique Scanning Laser Ophthalmoscopy oSLO and Optical Coherence Tomography OCT
12:22

Multimodal Volumetric Retinal Imaging by Oblique Scanning Laser Ophthalmoscopy oSLO and Optical Coherence Tomography OCT

Published on: August 4, 2018

9.1K

Hand scanning optical coherence tomography imaging using encoder feedback.

Nicusor Iftimia, Gopi Maguluri, Ernest W Chang

    Optics Letters
    |December 16, 2014
    PubMed
    Summary
    This summary is machine-generated.

    Researchers developed a new way to capture high-resolution images of internal body tissues using a handheld probe. By attaching a special sensor that tracks the probe's position, the system can create clear pictures even when the operator moves their hand. This technology is designed to work through thin biopsy needles, allowing doctors to easily inspect specific areas inside the body. The team also created a computer program to fix small image errors caused by tissue movement. This tool provides medical professionals with more flexibility during diagnostic procedures.

    Keywords:
    medical imagingdiagnostic toolsinterstitial tissuespatial registrationmotion artifacts

    Frequently Asked Questions

    More Related Videos

    Optical Coherence Tomography: Imaging Mouse Retinal Ganglion Cells In Vivo
    08:17

    Optical Coherence Tomography: Imaging Mouse Retinal Ganglion Cells In Vivo

    Published on: September 22, 2017

    20.5K
    Doppler Optical Coherence Tomography of Retinal Circulation
    10:46

    Doppler Optical Coherence Tomography of Retinal Circulation

    Published on: September 18, 2012

    19.4K

    Related Experiment Videos

    Last Updated: Apr 19, 2026

    Multimodal Volumetric Retinal Imaging by Oblique Scanning Laser Ophthalmoscopy oSLO and Optical Coherence Tomography OCT
    12:22

    Multimodal Volumetric Retinal Imaging by Oblique Scanning Laser Ophthalmoscopy oSLO and Optical Coherence Tomography OCT

    Published on: August 4, 2018

    9.1K
    Optical Coherence Tomography: Imaging Mouse Retinal Ganglion Cells In Vivo
    08:17

    Optical Coherence Tomography: Imaging Mouse Retinal Ganglion Cells In Vivo

    Published on: September 22, 2017

    20.5K
    Doppler Optical Coherence Tomography of Retinal Circulation
    10:46

    Doppler Optical Coherence Tomography of Retinal Circulation

    Published on: September 18, 2012

    19.4K

    Area of Science:

    • Biomedical engineering and optical coherence tomography imaging systems
    • Medical instrumentation and diagnostic device development

    Background:

    Current medical imaging techniques often struggle to provide high-resolution views of interstitial tissues during manual procedures. Clinicians frequently face limitations when attempting to capture stable images using handheld probes in confined spaces. No prior work had resolved the instability issues inherent in freehand scanning without complex external tracking systems. Existing methods typically rely on rigid mechanical mounts that restrict the operator's range of motion. That uncertainty drove the development of new approaches to stabilize image acquisition during clinical interventions. Researchers have long sought ways to integrate movement tracking directly into portable diagnostic tools. This gap motivated the exploration of encoder-based feedback mechanisms for real-time spatial registration. The integration of such sensors represents a shift toward more versatile and user-friendly diagnostic platforms.

    Purpose Of The Study:

    The study aims to introduce a novel method for generating micron-scale images of interstitial tissue using a handheld scanning probe. Researchers sought to overcome the limitations of traditional imaging systems that require rigid mechanical mounts. This work addresses the challenge of maintaining stable image acquisition during freehand diagnostic procedures. The team specifically investigated the use of a linear optical encoder to track probe movement relative to the tissue surface. They aimed to provide physicians with greater freedom to access and inspect specific anatomical sites repeatedly. The motivation stems from the need for more versatile and portable diagnostic equipment in clinical environments. By integrating motion-sensing technology, the authors intended to simplify the visualization of internal structures through narrow biopsy needles. This research establishes a framework for improving the usability of handheld diagnostic devices in medical practice.

    Main Methods:

    Review Approach framing involves analyzing the performance of a novel handheld probe integrated with a linear optical encoder. The design utilizes a fixed reference point on the tissue surface to track spatial coordinates during manual operation. Investigators implemented a software algorithm to detect and rectify artifacts resulting from tissue noncompliance. This process relies on identifying the repetition of adjacent A-scans to ensure image consistency. The experimental setup demonstrates high-resolution visualization capabilities through a long, narrow biopsy needle. Researchers evaluated the system by comparing freehand scanning results against standard imaging expectations. Data acquisition focuses on maintaining micron-scale resolution despite the inherent instability of manual probe manipulation. This methodology prioritizes user-controlled access to internal anatomical structures during diagnostic tasks.

    Main Results:

    Key Findings From the Literature indicate that the system successfully generates micron-scale images of interstitial tissue using a handheld probe. The researchers demonstrate high-resolution optical visualization through a very long biopsy needle. Their software algorithm effectively corrects minor artifacts caused by tissue noncompliance during the procedure. The method relies on detecting the simple repetition of adjacent A-scans to maintain image quality. This approach allows for the consistent capture of visual data despite the variability of manual scanning. The authors report that the encoder feedback provides accurate spatial registration relative to the tissue surface. This technique enables physicians to access imaging sites of interest repeatedly without requiring rigid mechanical support. The results confirm that the integration of motion-sensing hardware significantly enhances the utility of portable diagnostic tools.

    Conclusions:

    The authors propose that their encoder-based system successfully enables high-resolution imaging of biological tissues through narrow biopsy needles. This approach provides physicians with increased flexibility to access and re-examine specific anatomical sites of interest. The team suggests that their software algorithm effectively mitigates minor artifacts arising from tissue noncompliance during the scanning process. Synthesis and implications indicate that this method simplifies the acquisition of micron-scale visual data in clinical settings. The researchers demonstrate that tracking probe movement relative to a fixed reference point maintains image integrity. This work highlights the potential for integrating motion-sensing technology into standard diagnostic biopsy equipment. The findings suggest that freehand scanning can achieve diagnostic quality comparable to fixed-mount systems. Future clinical utility relies on the portability and ease of use offered by this handheld configuration.

    The researchers propose a method using a linear optical encoder to track probe movement relative to the tissue surface. This mechanism allows the system to generate micron-scale images while the operator manually scans the area, correcting for motion artifacts through a specialized software algorithm.

    The system utilizes a linear optical encoder, which acts as a sensor to detect the precise position of the probe. This component is essential for maintaining spatial registration during the scanning process, ensuring that the collected data accurately represents the interstitial tissue structure.

    A fixed reference point, specifically the tissue surface, is necessary to provide a stable baseline for the encoder. Without this external anchor, the system would be unable to calculate the relative displacement of the probe during the manual scanning procedure.

    The encoder feedback data serves as the primary input for spatial registration, while the software algorithm processes the raw signals to correct for tissue noncompliance. This combination ensures that the final images remain clear despite potential irregularities in the scanning motion.

    The researchers measure the repetition of adjacent A-scans to identify and remove artifacts. This phenomenon occurs when tissue movement causes inconsistencies in the scan, which the software then adjusts to produce a coherent final image.

    The authors claim that this handheld approach grants physicians the freedom to repeatedly access imaging sites of interest. This flexibility contrasts with traditional rigid imaging setups, which often limit the operator's ability to adjust the probe position during a procedure.