Assessment of Physical Activity Intensity with Accelerometers and Oxygen Consumption
Published on: June 20, 2025
Lifesource XL-18 pedometer for measuring steps under controlled and free-living conditions
Sam Liu1, Dina Brooks, Scott Thomas
1a Institute of Medical Science , University of Toronto , Toronto , Ontario , Canada.
Abstract:
The primary aim was to examine the criterion and construct validity and test-retest reliability of the Lifesource XL-18 pedometer (A&D Medical, Toronto, ON, Canada) for measuring steps under controlled and free-living activities. The influence of body mass index, waist size and walking speed on the criterion validity of XL-18 was also explored. Forty adults (35-74 years) performed a 6-min walk test in the controlled condition, and the criterion validity of XL-18 was assessed by comparing it to steps counted manually. Thirty-five adults participated in the free-living condition and the construct validity of XL-18 was assessed by comparing it to Yamax SW-200 (YAMAX Health & Sports, Inc., San Antonio, TX, USA). During the controlled condition, XL-18 did not significantly differ from criterion (P > 0.05) and no systematic error was found using Bland-Altman analysis. The accuracy of XL-18 decreased with slower walking speed (P = 0.001). During the free-living condition, Bland-Altman analysis revealed that XL-18 overestimated daily steps by 327 ± 118 than Yamax (P = 0.004). However, the absolute percent error (APE) (6.5 ± 0.58%) was still within an acceptable range. XL-18 did not differ statistically between pant pockets. XL-18 is suitable for measuring steps in controlled and free-living conditions. However, caution may be required when interpreting the steps recorded under slower speeds and free-living conditions.
More Related Videos
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Measurement of Blood Pressure