Removing a misplaced retropubic midurethral sling from the urethra and bladder neck using ear, nose, and throat
Ellen R Solomon1, J Eric Jelovsek
1Center for Urogynecology and Pelvic Reconstructive Surgery, Obstetrics, Gynecology & Women's Health Institute, Cleveland Clinic, Cleveland, Ohio.
Background:
The retropubic tension-free vaginal tape (TVT) procedure is a common procedure with complications attributed to voiding dysfunction, bladder perforation, and bleeding. We present a case of successful removal of a retropubic midurethral sling from the urethra using a head lamp and a combination of ear, nose, and throat instruments.
Case:
A 63-year-old woman presented to our clinic with the symptom of gross hematuria after having undergone a TVT procedure. On office cystoscopy, the sling was noted to be placed within the urethral mucosa. Removal of the mesh was performed using a nasal speculum, left and right ethmoid scissors, left and right Blakesley graspers, and a head lamp to dissect the mesh directly out of the urethra.
Conclusion:
The utilization of ear, nose, and throat tools allowed us to resect the intraurethral mesh without necessitating incision of the urethral sphincter.
Related Concept Videos
Urologic Endoscopic Procedure: Cystoscopic Examination
Urinary Bladder
In males, the bladder is situated in front of the rectum, while in females, it is positioned anterior to the vagina and uterus. The bladder floor contains an inverted triangular area called the trigone, defined by the two ureteric...
Imaging Studies VI: Voiding Cystourethrography and Cystography
Anatomy of the Genitourinary System II: Bladder and Urethra
Urinary Tract Calculi VI: Surgical Management
Ureters