Objective/Hypothesis:
In this study, optical coherence tomography (OCT) is used to noninvasively and quantitatively determine tympanic membrane (TM) thickness and the presence and thickness of any middle-ear biofilm located behind the TM. These new metrics offer the potential to differentiate normal, acute, and chronic otitis media (OM) infections in pediatric subjects.
Study Design:
Case series with comparison group.
Methods:
The TM thickness of 34 pediatric subjects was acquired using a custom-built, handheld OCT system following a traditional otoscopic ear exam.
Results:
Overall thickness (TM and any associated biofilm) was shown to be statistically different for normal, acute, and chronic infection groups (normal-acute and normal-chronic: P value < 0.001; acute-chronic: P value = 0.0016). Almost all observed scans from the chronic group had an accompanying biofilm structure. When the thickness of the TM and biofilm were considered separately in chronic OM, the chronic TM thickness correlated with the normal group (P value = 0.68) yet was still distinct from the acute OM group (P value < 0.001), indicating that the TM in chronic OM returns to relatively normal thickness levels.
Conclusion:
Identifying these physical changes in vivo provides new metrics for noninvasively and quantitatively differentiating normal, acute, and chronic OM. This new diagnostic information has the potential to assist physicians to more effectively and efficiently screen, manage, and refer patients based on quantitative data.
Level Of Evidence:
4.
Related Concept Videos
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...